Sign In | Join Free | My chinaqualitylighting.com
chinaqualitylighting.com
Products
Search by Category
Wholesale Marketplace
Home > Power Tools >

Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000

Categories Redundant Power Supply Module
Brand Name: Schneider
Model Number: 140ACO02000
Place of Origin: FR
MOQ: 1
Price: negotiable
Payment Terms: T/T, Western Union
Supply Ability: 100
Delivery Time: 2-3 work days
Packaging Details: New in original box
Brand: Schneider
Model: 140ACO02000
Palce of Origin: FR
Type: Processor/Controller
voltage drop: 30 V 20 mA
module format: Standard
analogue output number: 4
Weight: 0.37 kg
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000

    Redundant Power Supply Module Schneider Electric 140ACO02000 Analog output TSC Quantum


    Main
    range of product
    Modicon Quantum automation platform
    product or component type
    Analogue output module
    Complementary
    analogue output number
    4
    addressing requirement
    4 output words
    loop voltage
    12...30 V DC
    voltage drop
    30 V 20 mA
    analogue output range
    4...20 mA 0...4096 counts, 12 bits bipolar current
    absolute accuracy error
    +/- 0.20 % of full scale at 77 °F (25 °C)
    linearity
    +/- 1 LSB
    accuracy drift according to temperature
    +/- 0.004 % of full scale/°C
    +/- 0.007 % of full scale/°C maximum
    isolation between channels
    500 V 47...63 Hz AC
    750 V for 1 minute DC
    update time
    3 ms
    setting time
    900 µs to +/- 0.1 % of the final value
    fault type
    Open circuit 4...20 mA
    bus current requirement
    480 mA
    power dissipation in W
    <= 5.3 W
    external power requirement
    12...30 V
    marking
    CE
    local signalling
    4 LEDs green channel is turned on
    4 LEDs red channel fault
    1 LED green bus communication is present (Active)
    1 LED red external fault
    module format
    Standard
    product weight
    0.66 lb(US) (0.3 kg)
    Environment
    product certifications
    CUL
    FM Class 1 Division 2
    standards
    CSA C22.2 No 142
    UL 508
    resistance to electromagnetic fields
    9.14 V/yd (10 V/m) 80...2000 MHz conforming to IEC 801-3
    ambient air temperature for operation
    32...140 °F (0...60 °C)
    ambient air temperature for storage
    -40...185 °F (-40...85 °C)
    relative humidity
    95 % without condensation
    operating altitude
    <= 16404.2 ft (5000 m)
    Ordering and shipping details
    Category
    18155 - QUANTUM I/O & POWER SUPPLIES
    Discount Schedule
    PC21
    GTIN
    00785901792192
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    1.02
    Returnability
    Y
    Country of origin
    FR
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant - since 0750 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months

    OTHER SUPERIOR PRODUCTS

    Yasakawa Motor, Driver SG-Mitsubishi Motor HC-,HA-
    Westinghouse Modules 1C-,5X-Emerson VE-,KJ-
    Honeywell TC-,TK-GE Modules IC -
    Fanuc motor A0-Yokogawa transmitter EJA-
    Contact person: Anna
    E-mail: wisdomlongkeji@163.com
    Cellphone: +0086-13534205279

    Estimated Shipping Size
    Dimensions: 10" x 3" x 5" (25 cm x 8 cm x 13 cm)
    Weight: 0 lbs 13 oz (0.37 kg)


    Product Related Warnings

    Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us.


    No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric.


    All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to ensure compliance with documented system data, only the manufacturer should perform repairs to components. When controllers are used for applications with technical safety requirements, please follow the relevant instructions.


    Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this product related warning can result in injury or equipment damage.


    Inserting a module (local)


    1 Call the Bus Editor
    2 Mark a free slot in the local station (left mouse button)
    3 Move the mouse pointer over the marked slot
    4 Click on the right mouse button
    Result: A shortcut menu is opened


    5 Select New Device
    Result: A dialog window opens that displays all available modules
    6 Select the desired module from the respective category in the Hardware catalog.
    Result: The new module is inserted in the empty slot on the local station.


    Introduction

    The Modicon Quantum with Unity modules follow a system of flat address mapping. To work properly. each module requires a determinate number of bits and/or words. The IEC addressing system is equivalent to the 984LL register addressing. Use the following assignments:

    z 0x is now %Mx z

    1x is now %Ix z

    3x is now %IWx z

    4x is now %MWx Use the following table to convert 984LL notation to IEC notation.


    Examples

    The following examples show the relationship between 984LL register addressing and IEC addressing: 000001 is now %M1 100101 is now %I101 301024 is now %IW1024 400010 is now %MW10


    IODDT Addressing

    An IODDT allows all information (bits and registers) related to a channel to be handled through a user-defined variable. This variable is defined in the Unity Pro data editor by selecting the appropriate IODDT for the module as a data type and specifying the topological address of the module using the following syntax: %CH[b.e]r.m.c where: z b = bus z e = equipment (drop) z r = rack z m = module slot z c = channel Here is an example of an IODDT for an thermocouple input module in slot 4 of a local rack:



    Variables in the User Program

    You can access all information related to channel 1 of the module using the following variables: z My_Temp_Point1.VALUE for the measured value z My_Temp_Point1.ERROR indicating an out-of-range condition z My_Temp_Point1.WARNING indicating an over-range condition


    Word Addressing versus Bit Addressing

    Mainly discrete I/O modules can be configured to deliver their I/O data either in word format or in bit format. This can be selected during configuration by selecting either %IW (%MW) or %I (%M). If you need to access a single bit from an I/O module configured to use an I/O word, you can use the syntax %word.bit. The following table gives you the connection between I/O point number and the belonging I/O address in bit and word addressing. The table shows an 32-point input module in the main rack, slot 4 configured with starting address %I1 or %IW1:

    I/O channel Bit address (flat addressing) Bit address (topological addressing) Bit address extracted from word (flat addressing) Bit address extracted from word (topological addressing) 1 %I1 %I1.4.1[.0] %IW1.15 %IW1.4.1.1.15 2 %I2 %I1.4.2[.0] %IW1.14 %IW1.4.1.1.14 3 %I3 %I1.4.3[.0] %IW1.13 %IW1.4.1.1.13 • • • 15 %I15 %I1.4.15[.0] %IW1.1 %IW1.4.1.1.1 16 %I16 %I1.4.16[.0] %IW1.0 %IW1.4.1.1.0 17 %I17 %I1.4.17[.0] %IW2.15 %IW1.4.1.2.15 18 %I18 %I1.4.18[.0] %IW2.14 %IW1.4.1.2.14 • • • 31 %I31 %I1.4.31[.0] %IW2.1 %IW1.4.1.2.1 32 %I32 %I1.4.32[.0] %IW2.0 %IW1.4.1.2.0


    The 16-point output modules are as follows: z

    140DAO84000 (AC Output 24 ... 230 Vac 16x1) z

    140DAO84010 (AC Output 24 ... 115 Vac 16x1) z

    140DAO84210 (AC Output 100 ... 230 Vac 4x4) z

    140DAO84220 (AC Output 48 Vac 4x4) z

    140DDO84300 (DC Output 10 ... 60 VDC 2x8 Source) z

    140DRA84000 (Relay Output 16x1 Normally Open)


    The following list shows the 32-point output modules: z

    140DAO85300 (AC Output 230 Vac 4x8 Sink) z

    140DDO15310 (DC Output 5 V 4x8 Sink) z

    140DDO35300 (DC Output 24 Vdc 4x8 Source) z

    140DDO35301 (DC Output 24 Vdc 4x8 Source) z

    140DDO35310 (DC Output 24 Vdc True Low 4x8 Sink)


    CAUTION

    /O Mapping When I/O mapping module inputs using discrete %I references in remote drops, users should not split discrete words between drops. The lowest discrete reference for a drop should start on a word boundary. Failure to follow this instruction can result in injury or equipment damage.



    Buy Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000 at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Français| Русский язык| Español| Português| 日本語

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 chinaqualitylighting.com. All rights reserved.