Sign In | Join Free | My chinaqualitylighting.com |
|
Categories | Digital I O Module |
---|---|
Brand Name: | AB |
Model Number: | 1747-ASB |
Place of Origin: | USA |
Price: | negotiation |
Payment Terms: | T/T |
Supply Ability: | 1 |
Delivery Time: | 5-8 work daysRockwell Automation |
Packaging Details: | New in original boxRockwell Automation |
Condition: | new |
Nominal output voltage: | 120 / 240 VAC |
Product Type: | input Module |
warranty: | 1 year |
Memory Requirement: | 4 bytes |
Rated Voltage: | 1Watts |
Output Voltage Range: | -20 to +20 mA (or) -10 to +10V dc |
Communication rate: | 5.1 mA at 24V dc |
Company Info. |
Wisdomlong Technology CO.,LTD |
View Contact Details |
Product List |
AB 1747-ASB I/O ADAPTER MODULE SLC500 REMOTE SLC 500 57.6 KBIT/S
115 KBIT/S 230 KBIT/S
About 1747-ASB :
The AB 1747-ASB is a remote I/O adapter module that is part of the
SLC 500 system. It establishes a communication link between SLC or
PLC scanners and various 1746 I/O modules via Remote I/O. The
Remote I/O link consists of one master device i.e., an SLC or PLC
scanner and one or more slave devices that are adapters. The SLC or
PLC image table gets I/O module image-mapping directly from its
chassis. For image mapping, it supports both discrete and block
transfer. The 1747-ASB has support for 1/2-slot, 1-slot, and 2-slot
addressing with efficient image utilization. It is installed in the
chassis with the SLC 500 processor and it scans I/O in the chassis.
The 1747-ASB module has 375 mA backplane current at 5V and 0 mA at
24V. It has a minimum and maximum thermal dissipation of 1.875 W.
It can communicate I/O data over a distance of up to 3040 meters
and it supports 57.6K, 115.2K, and 230.4K baud rates. It allows a
user-selected image size of up to 32 logical groups and it controls
up to 30 chassis slots. The 1747-ASB also provides non-volatile
memory and extended node capability to up to 32 adapters. For
wiring, the Belden 9463 or similar category cable must be used, and
it does not require any user programming. It uses a 6-Pin Phoenix
Connector for connection between the Remote I/O link and the
processor. The 1747-ASB module supports all SLC 501 I/O modules
like basic modules, resistance modules, high-speed counter modules,
etc. For troubleshooting and operation, it has three 7-segment
displays with enhanced capability for displaying operating status
and errors. The 1747-ASB is intended for use in an Industrial
environment and provides a NEMA standard noise immunity.
The 1747- ASB is a Remote IO adapter that belongs to the SLC 500
automation platform. This IO adapter communicates with I/O scanner
modules, interface cards and gateways to establish Remote IO
connectivity.
For PLC applications, the primary purpose of this module is to
implement distributed IO application over a Remote I/O network.
Compared to an SLC expansion bus, the expansion has limited cable
length and a very limited SLC chassis expansion. With a 1747-ASB,
up to 32 SLC Chassis with 1747 RIO scanner may be used with
applicable distances of 762 meters or 2500 feet for 230.4 KBaud,
1524 meters or 5000 feet for 115.2 KBaud and 3048 meters or 10,000
feet for 57.6 KBaud. Up to 30 is the control capability of this
adapter, this 30 slot limit can be segmented to different chassis
or rack with each rack installed with a RIO scanner and a power
supply.
Aside from communicating with Remote IO scanners, this module may
also be used to communicate with AB communication cards that are
directly mounted to a personal computer. This enables remote
programming and configuration capability and remote control via a
Supervisory Control And Data Acquisition (SCADA). Alternatively, AB
Human Machine Interfaces (HMI) such as PanelView products are
capable of being added with a Remote I/O adapter that allows the
HMI to control the process similar to a SCADA system.
More information:
Manufacturer | Rockwell Automation |
Brand | AB |
Part Number/Catalog No. | 1747-ASB |
Series | SLC 500 |
Module Type | I/O Adapter Module |
Communication Port | Universal Remote I/O Adapter |
Communication Rate | 57.6, 115 or 230 kilobits/second |
Backplane Current (5 Volts DC) | 375 milliamps |
Cable | Belden 9463 |
Check publication for error codes and explanations on the meaning of these codes.
Ensure dip switches are configured correctly, publication will also help with this process.
Check to see that the RIO cable is properly terminated on both ends.
Visually inspect RIO communications cable for damages if possible.
If using a scanner module be sure to double check configuration as well as G-Data used in programming
Visually check the module for damage such as burnt out components broken board as well as terminating pins that insert into the backplane.
Ensure the rack that the ASB module is being plugged into is in good working condition
Our brand:
1, First, send us the brand, model code/pic of the nameplate, the quantity for inquiry. Then we will send the quote to you. after confirming the model and the quantity, then we will the PI to you.
2, You can transfer by Paypal/ Western Union/Trade assurance/ T/T. When we received the payment, then we will start to prepare the order for you asap.
![]() |