| Sign In | Join Free | My chinaqualitylighting.com |
|
| Categories | EV Battery Testing Equipment |
|---|---|
| Brand Name: | Neware |
| Model Number: | CE-6002n-150V200A-H |
| Certification: | CE |
| Place of Origin: | China |
| MOQ: | 1 Unit |
| Price: | USD negotiation per Unit |
| Payment Terms: | T/T |
| Supply Ability: | 50 Units Per Month |
| Delivery Time: | 45 working days |
| Packaging Details: | Wooden Box , W - D - H , 700 - 700- 1800 mm |
| Voltage Range: | 15V - 150V |
| Current Range: | 1A - 200A |
| Accuracy: | 0.05 percent of FS |
| Input power: | 67 KW |
| Stability: | 0.1 percent of FS |
| Min pulse width: | 100ms |
| Company Info. |
| Neware Technology Limited |
| View Contact Details |
| Product List |
Neware 150V200A Electric Vehicles Battery HPPC Pulse Simulated Condition Tester
CE - 6000 module pack testing system is a high - precision charging and discharging equipment specially developed for high - power battery pack testing . It has the characteristics of high dynamic response speed , high stability precision , multi - channel flexible configuration and so on . It supports pulse testing , cycle life testing and working condition simulation testing . The system has the function of multi - channel input and energy recovery , which can save a lot of electric energy consumed in the process of charging and discharging . Using bidirectional high - frequency DC converter topology and high - performance multi - channel 24 bit AD converter chip , the sampling resolution is higher than that of traditional single range equipment .
Technical characteristics
1 . High efficiency and energy saving
With bidirectional DC / DC and DC / AC power units , the battery
discharge energy can be efficiently fed back , the input of air
conditioning and exhaust system can be reduced , and the production
cost can be reduced .
2 . Fast response
DC / DC adopts single CPU control , reduces data communication time
and dynamic conversion time less than 10 mS , which is superior to
parallel power unit system .
3 . Excellent performance
The controller is designed with high - speed and high - precision
sampling control chip, optical fiber driver and self - made driver
board . It has strong anti - interference ability , system
conversion efficiency more than 94 percent , grid - connected
harmonics less than 3 percent , power factor more than 0.99 ,
charging and discharging accuracy less than 0.1 percent .
4 . Patent Heat Dissipation
The EBM centrifugal fan imported from Germany , the patented scheme
of upper and lower air inlet and outlet heat dissipation , the
efficient design of heat dissipation duct , good heat dissipation
effect and low temperature rise of the device can effectively
reduce dust and sand entering the cabinet and prolong the life of
the product .
Charge | Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power | |
| Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | ||
Discharge | Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance | |
| Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity | ||
Pulse | Charge | Constant current , Constant power |
| Discharge | Constant current , Constant power | |
| Min pulse width | 100ms | |
| Pulse counts | Each pulse step supports 32 different pulses | |
| Chg and Dschg switch | Supported | |
| Cut-off condition | Voltage, Time | |
| Simulated Condition | Charge mode | Constant current , Constant power |
| Discharge modes | Constant current , Constant power | |
| Cut-off condition | Time , Line Number | |
| Continuous switching Chg and Dischg | One simulation step can realize a continuous switching from charging to discharging | |
| Limit step number | 1 million | |
Cycle | Max cycles | 65535 |
| Max steps | 254 | |
| Cycle nest | Nested loop Function,Max Support 3 Layers | |
| Charge and discharge efficifency | more than 90 percent | |
| Protection | Anti - surge , anti - islanding , over - under - frequency , over - under - voltage , phase - loss protection , etc . | |
| Protection grade | IP20 | |
| Channel parallel | Supported , parallel channels do not support pulse and simulation testing | |
| Energy feedback | The discharge energy can be fed back to the power grid | |
| Noise | less than 65dB |
| Database | MySQL |
| Communication | TCP / IP |
| Operating system | Windows 7 / 10 64bit |
| Data export | EXCEL , TXT |
| Min. disk drive | 500GB |
| Communication port | Ethernet port |
| Communication port | CAN communication module support the communication with BMS to obtain the single voltage and temperature in BMS |

|