Sign In | Join Free | My chinaqualitylighting.com
chinaqualitylighting.com
Products
Search by Category
Wholesale Marketplace
Home > Measuring & Analysing Instrument Processing Services >

Solid Insulation Material Electrical Strength Testing Machine IEC60243-1 Lab Tester

Categories Lab Testing Machine
warranty: 1 Year
customized support: OEM, ODM, OBM, Software reengineering
place of origin: Guangdong, China
brand name: DAXIAN
power: 6kw
Voltage: 220V
Type: Testing machine
Protection Class: IP57
Product name: IEC 60243 Electrical Strength Testing Machine Lab Tester
Keyword: IEC 60243-1,ASTMD149
Rated power: 5KVA
Power supply: AC 220V ±10%, 50Hz±1
Weight: 220KG
Standard: IEC60243-1:2013 IEC60243-2
Test voltage: AC 0-50 kV continuously adjustable DC 0-50 kV
Transformer capacity: 10 KVA
Voltage measurement accuracy: ≤ 2%
Leakage current selection: 1-20 mA
Price: CN¥14,285.80/cases >=1 cases
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Solid Insulation Material Electrical Strength Testing Machine IEC60243-1 Lab Tester

Solid Insulation Material Electrical Strength Testing Machine IEC60243-1 Lab Teter

Compliance with standards:

Meets the requirements of GB1408.1, IEC60243-1 "Test Methods for Electrical Strength of Solid Insulation Materials - Tests at Power Frequency", GB1408.2, IEC60243-2 "Test Methods for Electrical Strength of Solid Insulation Materials - Corresponding DC Voltage Test" GB/T1695-2005 "Determination of Power Frequency Breakdown Voltage and Withstand Voltage of Vulcanized Rubber" GB/T3333 GB12656 and ASTM D149 test standards.

Scope of application:

Mainly applicable to solid insulation materials such as plastics, films, resins, mica, ceramics, silicone, glass, insulation paints, etc., for measuring breakdown strength and withstand time at power frequency (48-62Hz) or corresponding DC voltage in air or liquid media. Suitable for continuous and uniform voltage boosting or step-by-step voltage boosting, apply AC/DC voltage to the sample until breakdown, measure the breakdown voltage value, and calculate the breakdown strength of the sample; Using a rapid voltage boost method, raise the voltage to the specified value and maintain it for a certain period of time until the sample does not break down. Set the specified value at this time as the withstand voltage value of the sample.

Usage:

Take out the discharge rod, straighten the telescopic rod, insert the other end of the grounding clip into the metal probe hole of the discharge rod, and then clamp the grounding clip onto the instrument grounding terminal A or B. Hold the insulated handle as far away from the instrument housing as possible, stand up, bend forward slightly, open the glass door of the test box, and use the metal probe to touch the output voltage equalizing ball of the high-voltage transformer, the electrode on the sample, and the high-voltage end of the capacitor one by one. (If necessary, after the discharge is completed, use a multimeter in AC voltage mode (AC20V) to test that the voltage between the electrode and the human body is less than 36V, indicating that the residual voltage has been completely discharged.)
Attention: Before taking out the sample after each experiment, it is necessary to fully discharge it in advance. During discharge, the contact residence time at each discharge point should exceed 2 seconds.

Safety instructions:
1. The equipment needs to be equipped with a separate protective grounding wire. Grounding protection is mainly used to reduce the strong electromagnetic interference caused by the breakdown of the sample to the surrounding area. It can also prevent the computer from losing control.
2. The circuit of the experimental equipment is equipped with multiple protection measures, mainly including overcurrent protection, voltage loss protection, leakage protection, short circuit protection, DC test discharge alarm, etc.
3. Grounding requirements: Separate grounding is required, and the grounding should comply with national standards. The metal rod should be buried at least 1.5 meters deep underground.
4. The circuit of the experimental equipment is equipped with multiple protection measures, mainly including overcurrent protection, voltage loss protection, leakage protection, short circuit protection, DC test discharge alarm, etc.

Welcome to visit our factory for sightseeing!

Supplier Company Name

Daxian Instrument Equipment CO.,Limited

Company Address

Changlian Industrial Building, 168 Zhenan West Road, Xiabian Community, Chang'an Town, Dongguan, Guang Dong, China

Contact Person

Sophia Su

Mobile Number

86-13266221899

Telephone Number

86-0769-82759287


Our Service

*Consulting support.

*Sample testing support.

*Factory Visiting

*Training support

*Installation support

*24 Hours &7 days service


One-stop logistics:
The equipment is placed in the wooden box, covered with bubble film, with good shock absorption, impact resistance, heat sealing, and has the advantages of non-toxic, odorless, moisture corrosion resistance, transparency.One-stop comprehensive service to let you rest assured.

Buy Solid Insulation Material Electrical Strength Testing Machine IEC60243-1 Lab Tester at wholesale prices
Send your message to this supplier
 
*From:
*To: DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0