Sign In | Join Free | My chinaqualitylighting.com |
|
Categories | Stationary Power Source |
---|---|
Brand Name: | GENY |
Model Number: | YCS-103 |
Certification: | ISO, CE |
Place of Origin: | CHINA |
MOQ: | 1 pcs |
Price: | negotiation |
Payment Terms: | L/C,T/T,D/P |
Supply Ability: | 30 PCS per month |
Delivery Time: | 30 days after order confirmed |
Packaging Details: | Plywood case |
Accuracy class: | Class 0.02 |
Test voltage output: | 3*(24v-300v)or customized |
Test current output: | 3*(1mA-120A/200A) |
High power output: | (max. voltage power: 1000VA, current power: 1500VA) |
Company Info. |
Guangzhou GENY Electric Co., Ltd |
Verified Supplier |
View Contact Details |
Product List |
• Ultra-high accuracy and long-term stability for demanding
calibration tasks
• RS232 interface for seamless integration into automated
production lines
• Optional keypad for quick on-site manual control
• 2nd–21st harmonic: amplitude and phase fully programmable to
replicate real-world grid conditions
• Lightweight, rugged aerospace-grade aluminum alloy
housing—corrosion-resistant for tropical humidity
• Built-in protection against overload, short-circuit (voltage) and
open-circuit (current) for 24/7 safe operation
• Intuitive bilingual control software (English/Chinese interface)
– zero learning curve, ready in minutes
• National power utilities
• Government metrology & certification bureaus
• Leading energy-meter manufacturers (OEM/ODM support)
• International-grade quality, compliant with IEC 61000 & ANSI
C12.20
• High power output: up to 1000 VA (voltage) / 1500 VA (current) –
one unit replaces multiple sources
• Industry-leading power stability: temp drift <50 ppm/°C,
annual drift <0.01 %
• Total harmonic distortion <0.3 % on linear resistive load for
trustworthy calibration results
YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 | |
Voltage | ||||
Test voltage output (Phase-Neutral) | 3×(24V – 288V) or customized | |||
Power of the voltage output | 3×100VA | 3×250VA | 3×500VA | 3×1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current | ||||
Test current output | 3×(1mA – 100A) | |||
Power of the current output | 3×150VA | 3×350VA | 3×750VA | 3×1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Voltage Supply | 3×220/380V±10% or customized 50/60Hz±2Hz | |||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 85% |
![]() |