| Sign In | Join Free | My chinaqualitylighting.com | 
 | 
| Categories | Electronics Test Instruments | 
|---|---|
| Brand Name: | MEASTEK | 
| Model Number: | HCTL120KA | 
| MOQ: | 1 | 
| Payment Terms: | T/T,Western Union,MoneyGram | 
| Delivery Time: | 5-8 work days | 
| Sensitivity (mV/A): | 0.05 | 
| Current (KA): | 120 | 
| Maximum noise (mV Vpp): | 3 | 
| Attenuation characteristics (%/ms): | 0.06 | 
| Low frequency bandwidth -3dB(Hz): | 0.05 | 
| High frequency bandwidth -3dB(MHz): | 10 | 
| Typical accuracy: | 1% | 
| Insulation voltage value: | 10KV | 
| Company Info. | 
| Shenzhen Knowhow Technology Co.,limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
MEASTEK HCTL120KA High Precision Flexible Current Probe Ideal for Large Scale Substation Current Monitoring
1. High-frequency harmonic measurement: 10MHz bandwidth can effectively measure harmonics in current, meet the needs of large substations for power quality monitoring, help detect harmonic pollution in the power grid, and ensure stable operation of the power system.
2. Accurate phase shift detection: With 0.05mV/A sensitivity and 1% typical accuracy, it can
accurately measure the tiny phase shift of sine waves, playing a
key role in phase calibration and power factor optimization of
substation power equipment.
3. High voltage and high current adaptation: 10KV insulation withstand voltage, can be safely used for current
measurement in large substations with high current and high
voltage, whether it is bus current monitoring or transformer
winding current measurement, it can provide reliable data.
4. Flexible installation characteristics: The induction loop has an outer diameter of 8mm and is soft and
flexible. In the complex wiring environment of the substation, it
can easily measure current and can easily shuttle between various
types of equipment to meet the needs of different installation
locations.
5. Convenient power supply and connection: USB power supply with almost zero insertion loss, standard BNC
output interface for easy connection to professional measurement
equipment, convenient for engineers to monitor and analyze
substation current data, and improve work efficiency.
6. Customization to meet needs: Supports customization of probe ring and connection line length,
and can customize appropriate probe specifications according to the
layout and measurement requirements of different areas of the
substation to improve the convenience and accuracy of measurement.
Specifications
| Model | HCTL120KA | |
| Sensitivity (mV/A) | 0.05 | |
| Peak | Current (KA) | 120 | 
| dI/dt(KA/μs) | 40 | |
| Maximum noise (mV Vpp) | 3 | |
| Attenuation characteristics(%/ms) | 0.06 | |
| Low frequency bandwidth -3dB(Hz) | 0.05 | |
| High frequency bandwidth -3dB(MHz) | 10 | |
| Typical accuracy | 1% | |
| Insulation voltage value | 10KV | |
HCT(S)XXXXA Series Other Technical Parameters
| Maximum output voltage | 6Vpk | |
| Terminal load | ≥100kΩ | |
| Power supply mode | USB 5V (standard adapter) | |
| Operating temperature range | Integrator | 0℃ - 50℃ | 
| Probe ring | 0℃ - 100℃ | |
| Storage temperature range | -40℃~80℃ | |
Product Description

(Take HCTS0120A as an example)
1) Input interface: current probe test signal input terminal.
2) Output interface: current probe integrator signal output
terminal.
3) USB 5V power supply interface: standard USB (type B) interface.
(USB power supply cable and power adapter are standard)
4) Test connection diagram.

Mechanical specifications
| Model | HCTSXXXXA | 
| Typical value of flexible probe circumference (customizable) | 80mm | 
| Typical value of induction ring body diameter | 1.6mm | 
| Typical value of flexible probe diameter (customizable) | 25mm | 
| Induction loop connection cable length | 1 M (customizable) | 
| BNC connection cable length | 1 M or 2 M, 1 M is Standard | 
| Integrator body dimensions (including BN port dimensions) | About 110(L)*47(W)*30(H)mm | 
| USB cable (AM-BM) | About 1.8m | 
| USB output adapter | About 59mm*30mm*20mm | 
| Probe weight | About 150g | 
| Box weight (including probe) | About 960g | 
Care And Maintenance
1) Keep the probe clean and dry.
2) If cleaning is required, wipe with a soft dry cloth. Do not use
chemical cleaning agents.
3) When the probe is not in use, please put it in the packaging
provided and place it in a cool, clean and dry place.
4) When transporting the probe, be sure to put it in the packaging
provided by our company to prevent shock.
5) Do not pull the input and output lines hard to avoid excessive
twisting, bending or knotting.
Packing List
| Name | Quantity | 
| Current probe integrator | 1 piece | 
| Current probe flexible induction coil | 1 piece | 
| USB output adapter (5V/1A) | 1 piece | 
| USB power cable | 1 piece | 
| BNC output cable | 1 piece | 
| Electronic manual | 1 serving | 
|   | 
 UHCT0030A Ultra-high Frequency Flexible Current Probe 200mV/A High Sensitivity 50MHz Bandwidth For Semiconductor / low Voltage Circuit Detection
                                                                                    
                        
                        
                        
                                                            UHCT0030A Ultra-high Frequency Flexible Current Probe 200mV/A High Sensitivity 50MHz Bandwidth For Semiconductor / low Voltage Circuit Detection
                                                    
                        
                     UHCT0060A Wideband Current Probe 100mV/A Sensitivity For Capacitor Discharge Analysis Industrial Grade Temperature Resistant Design
                                                                                    
                        
                        
                        
                                                            UHCT0060A Wideband Current Probe 100mV/A Sensitivity For Capacitor Discharge Analysis Industrial Grade Temperature Resistant Design
                                                    
                        
                     UHCT0120A High Dynamic Current Probe 0.12kA Peak 70%/ms Attenuation , Anti-interference Design
                                                                                    
                        
                        
                        
                                                            UHCT0120A High Dynamic Current Probe 0.12kA Peak 70%/ms Attenuation , Anti-interference Design
                                                    
                        
                     UHCT0600A Industrial Grade Protection High Current Probe 0.6kA Peak Adaption IGBT Switch Analysis
                                                                                    
                        
                        
                        
                                                            UHCT0600A Industrial Grade Protection High Current Probe 0.6kA Peak Adaption IGBT Switch Analysis
                                                    
                        
                     MEASTEK UHCT1200A Customizable Ultra-high Current Probe With High Temperature Resistant Coil 15mV Low Noise For Welding Machine And Capacitor Discharge Detection
                                                                                    
                        
                        
                        
                                                            MEASTEK UHCT1200A Customizable Ultra-high Current Probe With High Temperature Resistant Coil 15mV Low Noise For Welding Machine And Capacitor Discharge Detection
                                                    
                        
                     MEASTEK UHCT3000A 3KA Lightweight Portable High Current Probe 80A/ns Transient Response For Power Grid Short Circuit Diagnosis , Anti-electromagnetic Interference
                                                                                    
                        
                        
                        
                                                            MEASTEK UHCT3000A 3KA Lightweight Portable High Current Probe 80A/ns Transient Response For Power Grid Short Circuit Diagnosis , Anti-electromagnetic Interference
                                                    
                        
                     UHCT6000A 6kA Ultra-high Voltage Probe 50MHz High Frequency Bandwidth 12mV Low Noise for Power Line Fault Detection
                                                                                    
                        
                        
                        
                                                            UHCT6000A 6kA Ultra-high Voltage Probe 50MHz High Frequency Bandwidth 12mV Low Noise for Power Line Fault Detection
                                                    
                        
                     UHCT012KA 12kA Lightning Current Probe 2.0% Attenuation Characteristics 0.5mV/A Sensitivity Extreme Environment Adaptation
                                                                                    
                        
                        
                        
                                                            UHCT012KA 12kA Lightning Current Probe 2.0% Attenuation Characteristics 0.5mV/A Sensitivity Extreme Environment Adaptation
                                                    
                        
                     UHCT030KA Industrial Grade Broadband Probe 8mV High Signal-to-noise Ratio For Arc Furnace / circuit Breaker Detection
                                                                                    
                        
                        
                        
                                                            UHCT030KA Industrial Grade Broadband Probe 8mV High Signal-to-noise Ratio For Arc Furnace / circuit Breaker Detection
                                                    
                        
                     UHCT060KA 8mV Ultra Low Noise Temperature Resistant Current Probe with 160A/ns Peak di/dt -3dB Low Frequency Bandwidth 0.5Hz
                                                                                    
                        
                        
                        
                                                            UHCT060KA 8mV Ultra Low Noise Temperature Resistant Current Probe with 160A/ns Peak di/dt -3dB Low Frequency Bandwidth 0.5Hz