Sign In | Join Free | My chinaqualitylighting.com |
|
Categories | Cable Fault Pinpointer |
---|---|
Certification: | CE, ISO |
Brand Name: | XZH TEST |
Model Number: | XHDD503 |
Place of Origin: | China |
MOQ: | 1unit |
Payment Terms: | T/T |
Supply Ability: | 2000piecs/Year |
Delivery Time: | 5-8 days |
Packaging Details: | wooden case |
Model NO.: | XHDD503 |
Power: | Electricity |
Customized: | Customized |
Color: | Black+Silver |
Nw: | 6.7kg |
Transport Package: | Exported Wood Case with Foam Inside |
Specification: | 350mm*280mm*170mm |
Trademark: | XZH TEST |
Origin: | China |
HS Code: | 9031809090 |
Customization: | Available |
After-sales Service: | Warranty Certificate |
Warranty: | 1 Year |
Company Info. |
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
XHDD503 Underground Cable Fault Pinpointer
Description
The XHDD503 cable fault locator is very small and light, it is
packed in a protective PVC case, easy to carry after the user
finished detection.
The XHDD503 power cable fault pinpointer is designed with a microammeter display, with electrical level
adjustment, frequency adjustment and volume adjustment knobs. By
observing the swing of pointer on the microammeter, you can see the
magnetic field strength during the flashover discharge at the fault
point. Rotate the electrical level knob to adjust the reference of
the magnetic field strength. In the process of path detection,
adjusting the receiving frequency can make our ears hear the path
signal that is easier to identify. Adjusting the frequency knob
during the process of fault location can effectively avoid the
radio signal. Adjust the volume during cable fault location and
cable path finding, so that our ears hear a more appropriate sound
signal.
Technical Parameters
Magnification | 500,000 times |
Positioning accuracy | ±0.2m |
Output impedance | 350Ω |
Working power supply | Standard 3.7V 3200mAh battery 4 cells |
Quiescent current | <10mA |
Detection depth: | More than 10 meters |
Working conditions | Ambient temperature: -25~65ºC; Relative humidity: ≤90%. |
Product Features
1. Synchronously receive vibration waves, sound waves and
electromagnetic waves generated during discharge at the fault
point;
2. The acoustic and magnetic channels are designed separately and
powered separately, with stronger anti-interference ability;
3. Super magnification, detection depth is greater than 10 meters;
4. Ultra-low and low-power design, quiescent current is less than
10mA, and continuous operation is more than 20 hours;
5. Analog meter design, signal strength and trend are clear at a
glance;
6. Zero level can be adjusted arbitrarily, suitable for various
strong and weak scenes.
Packing List
![]() |