| Sign In | Join Free | My chinaqualitylighting.com |
|
| Categories | Switchgear Power On Test Bench |
|---|---|
| MOQ: | 1 Set |
| Price: | US $1,400-13,800 / |
| Place of Origin: | China |
| Brand Name: | Sansion |
| Certification: | CE/CNAS/ISO9001 |
| Packaging Details: | Plywood Case |
| Payment Terms: | L/C T/T |
| Supply Ability: | 100 Units/Month |
| Model NO.: | SXGK |
| Max Diameter of Workpiece: | <500mm |
| Mass Scope of Workpiece: | <900kg |
| Type: | Strength Testing Machine |
| Maxcapacity: | >1000KN |
| Accuracy Grade: | 0.5 |
| Load Way: | Electronic Load |
| Loading Method: | Dynamic Load |
| Display: | Digital |
| Control: | Manual Control |
| Weight: | 0-100Kg |
| Power Source: | AC220V |
| Oil Cylinder Position: | Under |
| Input: | 3 Phase 4 Line AC 380V |
| Input Frequency: | 50Hz/60Hz |
| Test Project 1: | Electrical Function Test |
| Test Project 2: | Contact Resistance Test |
| Test Project 3: | Trip Coil Test |
| Test Project 4: | Close Coil Test |
| Test Project 5: | Protection Relay Tes |
| Test Project 6: | Current Transformer Tes |
| Test Project 7: | Voltage Transformer Test |
| Test Project 8: | Insulation Resistance Te |
| Test Project 9: | Hi-Pot Test |
| Test Project 10: | Mechanical Operation Test |
| Transport Package: | Plywood Case |
| Specification: | ISO9001 SGS |
| Trademark: | Sansion |
| Origin: | China |
| HS Code: | 9030899090 |
| Production Capacity: | 100 Units/Month |
| Company Info. |
| Sansion Power Electric Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
√ Direct Digital Readout
Test parameters such as current, voltage, and power factor are
displayed directly on digital meters.
√ High‑Accuracy Measurement
Utilizes high‑precision components to ensure accurate and reliable
test results.
√ Comprehensive Safety Protection
Each output circuit is individually protected by a circuit breaker
(air switch) to prevent overload.
√ Portable Design
Compact and lightweight construction ensures easy transportation
and on‑site deployment.
Connect the three-phase four-wire AC 380V input.
Connect the DC output voltage to the load.
Rotate the output adjustment knob counterclockwise to its zero position.
Verify and confirm that all wiring is correct.
Turn on the main power switch.
Gradually rotate the output adjustment knob clockwise to increase the voltage to the desired value.
After testing, first rotate the output adjustment knob counterclockwise back to the zero position, then turn off the main power switch. Wait until discharge is complete before disconnecting any wires.
√ Circuit Resistance Measurement
Test Current: 0‑100A / 0‑200A selectable
Measurement Range: 0‑2mΩ / 0‑20mΩ
√ Insulation Resistance Measurement
Test Voltage: 500‑2500V DC
√ Dielectric Withstand Voltage Test
Test Levels: 0.4kV, 10kV, 35kV AC
√ Short‑Time Withstand Current Test
Current Range: 0‑2000A
√ Relay & Contactor Functional Test
Applicable to various protection and control relays, contactors
√ Circuit Breaker Timing & Speed Characteristic Test
Measures opening/closing time and travel‑velocity characteristics
√ High & Low Voltage Switch Operational Test
Verifies on/off operation and mechanical performance







|