ACS713ELCTR-20A-T 20A Sensors Transducers Bi Directional Linear Current Sensor
![]() |
...Bi-directional Hall Effect-Based Linear Current Sensor 8-SOIC Package For Measuring DC Sensor Type Hall Effect, Open Loop Current - Sensing 20A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 185mV/A Frequency DC ~ 80kHz Linearity ±1.5% Accuracy ±1.5% Voltage - Supply 5V Response Time 5µs Current......
Shenzhen Sai Collie Technology Co., Ltd.
|
Hall Current Sensor 4V/5V/20mA/4-20mA For DC Motor Drive UPS
![]() |
Hall Current Sensor 4V/5V/20mA/4-20mA For DC Motor Drive UPS Production Description Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signal control of current signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback in the current...
Jiangsu Acrel Electrical Manufacturing Co., LTD.
|
YJJ L03S600D15WM 10μs 20mA bi-directional ±1% 600A A Hall current sensor is installed in the base
![]() |
Product Description: The Closed Loop Current Sensor is a highly reliable AC DC current sensor designed for accurate current detection in a wide range of applications. This product offers exceptional performance with key attributes that cater to the needs......
ShenzhenYijiajie Electronic Co., Ltd.
|
Good Linearity Hall Effect Current Sensor Bandwidth Fast Response
![]() |
... (direct) and closed loop (magnetic balance). The advantage of the direct-amplification Hall sensor is that the circuit form is simple and the cost is relatively low; the disadvantage is that the accuracy and linearity are poor, the response time is slow,...
Dongguan Chenglue Electronic co.,Ltd
|
Electrochemical Hall Effect Current Sensor , Clamp On Current Transducer
![]() |
... principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents. Directions for use 1. When the current will be measured goes through a sensor,...
Shaanxi Shinhom Enterprise Co.,Ltd
|
IEC60950 Open Loop Hall Effect Current Sensor Dismountable
![]() |
...Hall Effect Based Current Sensor Switched Mode Power Supplies Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals .After signals are convertedaccording to the Hall Effect Theory,the can be directly acquired by AD, DSP, PLC, secondary instruments and other devices.Hall current sensors are widel applicable for acquisition and feedback control of current signals in the current...
Nanjing Token Electronics Science&Technology Co., Ltd.
|
hall effect sensor of open loop sensor hall ipn 5-10000A for dc ac and pc measurement
![]() |
...sensor hall use the open loop hall direct testing principle to test direct current, alternating current and pulse current, the primary current is electrical isolation with secondary output signal. The output value can be customized. 2.The following is our detailed information of our hall effect sensor of open loop sensor hall ipn 5-10000A for dc ac and pc measurement Working Principle The magnetic flux produced by primary current......
Tianjin Grewin Technology Co., Ltd
|
Type B Type EV Use Ac Dc 6mA 30mA 4-20Ma Current Sensor Applications
![]() |
... the device is in operation, it can detect the output signals of each branch sensor in real time. When the branch insulation is normal, the current flowing through the sensor is equal in magnitude and opposite in direction, and its output signal is zero....
IVY METERING CO.,LTD
|
12v/24v dc motor linear push pull solenoid actuators with hall effect sensors, waterproof electric actuator
![]() |
No Compromise On Quality What We Can Do For You? Our team focuses on providing the best value solutions about linear actuator for your specific design and equipment requirements. We welcome the opportunity to work with you. Should you have questions, or ......
Sino linear actuator
|
MTL5544D Repeater Power Supply MTL Instruments 4/20ma For 2 Or 3 Wire Transmitters Two Outputs
![]() |
... located in a hazardous area, and repeats the current in other circuits to drive two safe-area loads. For HART 2-wire transmitters, the unit allows bi-directional transmission of digital communication signals superimposed on the 4/20mA loop current....
Achievers Automation Limited
|