CE UL Split Core Clamp-On Current Transformer 0 - 3000A AC Busbar For Power Analyser
![]() |
...Split Core Clamp-On Current Transformer 0 - 3000A AC Busbar For Power Analyser The model Q125 current clamp on measuring instrument can be used for a current vector for the copper bar or the power aluminum bus bar on-line detection. A common form of current clamp comprises a split ring made of ferrite or soft iron. A wire coil is wound round one or both halves, forming one winding of a current transformer. The conductor it is clamped...
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
|
1000A 0.05 Class Clamp On Current Transformer Ct AC Monitoring
![]() |
... 2, Mainly using for: 1). Clamp-on Current Transformer, 2). Clip on current transformer, 3). Current transformer clamp, 4). Current transformer 3, Technial index notes 1), Testing current: 100mA to 6, 000A 2), Accuracy class is divided into 0.1, 0.2, 0.5...
Hefei Hemei Electronics Technology Co., Ltd
|
High Precision Split Core low voltage current transformers Clamp On Current Transformer
![]() |
High Precision DP Series Split Core Current Transformer Clamp On Current Transformer Description : DPrange of split core current transformers have been designed to easily fit around cables without breaking the circuit.Its advantages of big capacity and big......
YUEQING YOMIN ELECTRIC CO., LTD
|
Customizable Split Core Current Transformer Clamp Type Current Transformer
![]() |
..., versatility, and low phase shift to theprobe for a good selection of application range of power measurement widely. Current clamp is portable AC current measuring device and the one-hand operating solution for temporary or long-term studies,with...
Shaanxi Shinhom Enterprise Co.,Ltd
|
Split Core Clamp On Current Transformer Flexible AC Clamp On CT
![]() |
... Clip on current transformer Current transformer clamp Current transformer Technial index notes Testing current: 100mA to 6, 000A Accuracy class is divided into 0.1, 0.2, 0.5 and 1.0 grade Primary current: 100mA to 6, 000A Secondary current: 1mA to...
ERFA Industries Group
|
Ring Main Unit C - GIS LV Clamp On Current Transformer Split Core
![]() |
Ring Main Unit C-GIS LV Current Transformer Split Core Clamp-on Type 1. Product Introduction: High quality epoxy resin poured into inflaming retarding PVC ring Doss hell is adopted in two ......
Shenzhen Chuangyin Co., Ltd.
|
clamp on current transformer rated input 1a 5a 10a rated output 1ma 2ma 2.5ma 4ma 5ma 10v
![]() |
...Clamp-on) current transformer has been specially designed to facilitate their installation in new or already existing net works.They may be installed without opening any cable or bus-bar circuit. An internal precision resistor across the secondary winding of the CT provides a low safe voltage output. It can save time and the installation costs. Features Clamp......
Tianjin Grewin Technology Co., Ltd
|
IEC/EN61869-2 Standard Rectangular Split Current Transformer 50Hz AKH-0.66/K
![]() |
... Technical parameter ADL100-EY Voltage Reference voltage 3*220/380V Reference frequency 50Hz Consumption <4VA(Each phase) Current Input Current 1(6)A,10(80)A Starting Current Connect directly: 0.004 Ib, connect via...
Jiangsu Acrel Electrical Manufacturing Co., LTD.
|
4ohm AC Current Clamp Probe , Q8 Clamp On Current Transformer
![]() |
... type Output : down-lead output parameter: Primary current Secondary current Class % 5A 2mA 0.2,0.5 5A 2.5mA 0.2,0.5 5A 5mA 0.2,0.5 10A 4mA 0.2,0.5 10A 5mA 0.2,0.5 10A 10mA 0.2,0.5 Our advantage service We have our own ......
Zhengzhou Great Electric Co.,Ltd.
|
KCT-24 clamp-on current transformer split core current transformer 5a
![]() |
Product Description Model KCT-24 Current Ratio 100A/40mA 200A/40mA 200A/66.7mA 400A/80mA 100-400A/0.333V Primary Current (A) 100A 200A 200A 400A 100-400A Max. Current (A) 150A 240A 240A 480A 480A Output 40mA 40mA 66.7mA 80mA 0.333V Load Resistance (Ω) 50Ω ......
YUEQING RENHE ELECTRIC CO., LTD.
|