Sign In | Join Free | My chinaqualitylighting.com |
|
All 20ms response time gas sensors wholesalers & 20ms response time gas sensors manufacturers come from members. We doesn't provide 20ms response time gas sensors products or service, please contact them directly and verify their companies info carefully.
Total 3663 products from 20ms response time gas sensors Manufactures & Suppliers |
|
![]() |
Brand Name:RAE Model Number:4O2-LQ CLE-0231-400 Place of Origin:Britain ...30% O2 Electrochemical Oxygen Gas Sensor Features: Product Model: CLE-0231-400 Range: 0 to 30% O2 Maximum load: 90% O2 Output signal: -350 ±50 μA in air Baseline: -40 ~ 10 μA (nitrogen) Resolution: 0.1% O2 Response time (T90) : ≤ 30 seconds Linearity... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:3CO-500 CLE-0052-300 Place of Origin:Britain ...Carbon Monoxide CO Gas Sensor Features: Product Model: CLE-0052-300 Range: 0-500 ppm Maximum load: 1500 ppm Sensitivity: 0.08 +0.02uAVppm Baseline (20℃) : < ±0.2 μA Baseline drift: equivalent to 0to3ppm CO Resolution: 1 ppm Response time (T90) ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:3EF 3E/ F AB004-J08 Place of Origin:Britain ...Gas Sensor 3EF 3E/ F AB004-J08 Features: Nominal Range :0-1000ppm Maximum Overload:2000ppm Expected Operating Life:Three years in air Output Signal:0.10 ± 0.02 µA/ppm Inboard Filter (3E/F only):To remove SOx/NOx & H2S Resolution:0.5ppm Temperature Range:-20°C to +50°C Pressure Range:Atmospheric ± 10% Pressure Coefficient:0.020 ± 0.008 %signal/mBar T90 Response Time... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:3H2S-100 CLE-0112-300 Place of Origin:Britain ... Sulfide H2S Gas Sensor Features: Product model CLE-0112-300 Measuring range 0-100 ppm Maximum load 500 ppm Sensitivity 0.8 ± 0.2uAppm Baseline (20°C) : < +0.4 μA Baseline drift: equivalent to 0 to 0.2 ppm H2S Resolution 1 ppm Response time (T90) ≤30 ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:3HHLM AC005-J00 Place of Origin:Britain ... Hydrogen Sulfide (H2S) Gas Sensor Features: MEASUREMENT Operating Principle:3-electrode electrochemical Measurement Range:0-50 ppm H2S Maximum Overload:500 ppm H2S Filter:None Sensitivity:1.70 ± 0.30 μA/ppm Response Time (T90):<30 Seconds Baseline... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:4CFC 2112B2006 Place of Origin:Britain ...Gas Sensor Part Number: 2112B2006 Features: Nominal Range 0-1000 ppm CO Maximum Overload 2000 ppm CO Inboard Filter To remove H2S Expected Operating Life Two years in air Output Signal 0.37 ± 0.07 µA/ppm Resolution 0.5ppm Temperature Range -20° to +50°C Pressure Range Atmospheric ± 10% Pressure Coefficient 0.015 % signal/mBar T90 Response Time... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:4CL2-50 CLE-0951-400 Place of Origin:Britain ...Gas Sensor Used For Chlorine Leakage Monitoring In Chemical Pharmaceutical Plants And Other Places Features: Product model CLE-0951-400 Range 0 to 50 ppm Load 100 ppm Sensitivity 0.45 ± 0.20 mA/ppm Baseline (20℃) <± 0.1 ma Baseline drift is equivalent to 0 to 0.3 ppm (-20 to 40 ℃) Resolution 0.1ppm Response time... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:4SPE O2 CLE-0231-40S Place of Origin:Britain ... Monitoring Gas Sensor Features: Product model CLE-0231-40S Range 0 to 30% O2 Load 100 ppmSensitivity 1.4 ± 0.6 mA/ppm Baseline (20℃) <± 0.4 mA Baseline drift is equivalent to 0 to 0.5 ppm (-20 to 40℃)Resolution 0.1ppm Response time (T90) £60... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Model Number:4OL CLE-0231-400 Place of Origin:USA ...0231-400 O2 Electrochemical Gas Sensor Oxygen Detector Features: Product type CLE-0231-400 Measuring range 0 to 30% O2 Load 90% O2 Output signal 350 ± 50 μA in air Baseline <20 μa (nitrogen) Resolution 0.1% O2 Response time (T90) £30 seconds linearity ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Model Number:CS2/CF-100 CS2/CF-500 ...Gas Sensor Highly Selective And Sensitive CS2 Detection For Discontinuous Measurement Key Features: • Highly selective and sensitive CS2 detection • Ideal for TLV-TWA level measurements Applications: • Discontinuous Measurement • Safety and Process Control T90 Response Time... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:Excelitas Technologies Model Number:PYS3228TCG5G20/3506 Place of Origin:USA ...Gas Sensor Dual Analog Outputs Metal Material Applications *Gas Sensing and Monitoring Features and Benefits *T0-5 metal housing *Dual channel Output *Each channel with individual Filter window *Selection of narrow band pass filters *Thermal Compensation option Operation yoltage 2-12V Responsivity, min. 2.2Rmin Responsivity... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:FIGARO Model Number:TGS3830 Place of Origin:Japan ...Gas Sensor Features: TGS3830 is mainly used for portable refrigerant leakage detector, refrigerant leakage alarm, R-134A has high sensitivity, and fast response speed, TGS3830 is a low-cost portable refrigerant leakage alarm ideal sensor. 1 small size 2 low power consumption 3 has high sensitivity and fast response... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:Figaro Model Number:TGS832-A00 Place of Origin:Japan ... The sensitive element of the sensor consists of a tin biennial (S;02) semiconductor, which is The electrical conductivity in the air is very low. When the detected gas is in the air, the concentration of the gas is higher. Higher sensor rates will also |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:Consensic Model Number:CMF5019 Place of Origin:WUXI ... Method Air 20C 101.325 KPa Gas Sensors Unit Remarks Power Supply 8~24 VDC, 50 mA VDC Optional Accuracy ±1.5 % FS Response Time 65 ms Customizable Maximum Pressure 0.8 MPa Customizable Communication RS485 (MODBUS) Output Options Analog Output 1-5 V VDC ... |
Wuxi Consensic Electronic Technology Co., Ltd.
|
![]() |
Brand Name:CITY Model Number:HCL 3E 30 HCL3E30 1139-034-30049 Place of Origin:UK ...Gas Sensor product with model number 6812950 is a cutting-edge device designed to detect Hydrogen Chloride (HCL) gas with high precision and reliability. With a resolution of less than 0.7 ppm, this sensor is ideal for monitoring HCL levels in various industrial applications. The sensor operates on the principle of electrochemical detection, ensuring accurate and fast response to HCL gas presence. Its sensor... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Model Number:3SP-O3-5P ...gas sensors Small size and low profile BENEFITS • Small Size with Low Profile (20x20x3 mm) • Long Life (10 years expected life) • Fast Response (< 15 seconds) • Low Power Consumption • Individually Calibrated (NIST Traceable) • ROHS Compliant • Improved stability and ppb performance BENEFITS • Small Size with Low Profile (20x20x3 mm) • Long Life (10 years expected life) • Fast Response... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:FIGARO Model Number:TGS3830 Place of Origin:Japan ...Gas Sensor Is Used To Detect Refrigerant Leakage Alarms In Refrigerators And Air Conditioners Features: Freon Gas Sensor TGS3830 Introduction: TGS3830 is mainly used for portable refrigerant leak detector, refrigerant leak alarm, R-134a has extremely high sensitivity, and fast response, TGS3830 is a low cost This portable refrigerant leak alarm is the ideal sensor. First, Freon gas sensor... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:FIGARO Model Number:TGS2600 Place of Origin:Multi-origin ...Gas Sensor Product Features: • Highly sensitive to common combustible gases • Low power consumption • Robust construction • Long lifetime • Low cost Specifications: • Operating Voltage: 3V - 5V DC • Operating Current: 150mA • Operating Temperature: -20°C - 50°C • Sensitivity: 10-200ppm • Response Time: 150s • Sensor... |
Shenzhen Sai Collie Technology Co., Ltd.
|
![]() |
Brand Name:KACISE Model Number:KLBH-H5 Place of Origin:CHINA ...30s and a 130s ± 10s warming time, it provides timely protection. Mounted on the kitchen wall, it helps prevent fires and explosions. The device is designed to operate in a wide temperature range of - 10℃~... |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |
![]() |
Brand Name:KACISE Model Number:TDLAS200 Place of Origin:china TDLAS200 Fast-Response Methane Gas Detector 1.Introduction The KACISE TDLAS200 Fast-Response Methane Gas Detector is engineered for rapid and accurate methane detection, with a response time of just 0.1 seconds. It offers a detection range of 0~5000ppm... |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |