| Sign In | Join Free | My chinaqualitylighting.com |
|
All 30 ppm measurement range gas sensor wholesalers & 30 ppm measurement range gas sensor manufacturers come from members. We doesn't provide 30 ppm measurement range gas sensor products or service, please contact them directly and verify their companies info carefully.
| Total 1874 products from 30 ppm measurement range gas sensor Manufactures & Suppliers |
|
|
|
Brand Name:CITY Model Number:7E/F 7EF AB704-407 Place of Origin:UK ...: 0.1±0.02uA/PPM Resolution: 0.5 PPM Operating temperature: -20℃~+50℃ T90 Response time: ≤30S Operating humidity: 15~90%RH Zero drift: ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:MEMBRAPOR Model Number:NH3/SR-1000-S Place of Origin:Switzerland ...Gas Sensor 3 Electrode Electrochemical Safety And Environmental Control Applications • Leak Detection • Discontinuous Measurement • Safety and Environmental Control Datasheet: T90 Response Time < 50 s Typical Baseline Range (pure air, 20°C) - 16 ppm to 16 ppm Maximum Zero Shift (+20°C to +40°C) -32 ppm... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:CO-AX Place of Origin:UK ... Gas Sensor For Air Quality Monitoring Environmental Monitoring Systems 1. Product Features: High Measurement Accuracy & Sensitivity: Delivers a sensitivity range of 55 - 100 nA/ppm in 400 ppm CO, with a resolution of < 0.5 rms noise (ppm equivalent... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:DDS Model Number:GS+5CO Place of Origin:UK ...Gas Sensor Use In Portable Emissions Gas Detectors High Stability Introduction The GS+5C0 is a premium high quality robust CO sensor, ideal for use in portable emissions gas detectors Key Features: High stability, fast response and recovery, robust environmental performance. Measurement Range 0 - 4,000 ppm Maximum Overload 20,000 ppm... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:4CL2-50 CLE-0951-400 Place of Origin:Britain ...Gas Sensor Used For Chlorine Leakage Monitoring In Chemical Pharmaceutical Plants And Other Places Features: Product model CLE-0951-400 Range 0 to 50 ppm Load 100 ppm Sensitivity 0.45 ± 0.20 mA/ppm Baseline (20℃) <± 0.1 ma Baseline drift is equivalent to 0 to 0.3 ppm (-20 to 40 ℃) Resolution 0.1ppm Response time (T90) £30... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:Alphasense Model Number:NO-A1 Place of Origin:UK ... to 50ppm NO < 20 Zero current ppm equivalent in zero air 3 Resolution RMS noise (ppm equivalent) < 0.2 Range ppm NO limit of performance warranty 250 Linearity ppm error at full scale, linear at zero and 50ppm NO +32 to +36 Overgas range maximum ppm for |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:4CF+ 2112B2005 Place of Origin:UK ... %RH 15-90 Storage time month (storage temperature 3-20 ℃) 6 Load resistance ohm 10-100 Specifications: Gas Concentration Used (ppm) Reading (ppm CO) Carbon Monoxide 50 50 Hydrogen Sulfide 20 <5 Sulphur Dioxide 20 <5 Nitrogen Dioxide 20 -5 ≤ X $ ≤ 0 |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:H2S-A1 H2S-AE H2S-AH ...Gas Sensor Two Years Life Without Filter For Hydrogen Sulfide Gas Analyzer PERFORMANCE: Sensitivity nA/ppm in 20ppm H2S 550 to 875 Response time t90 (s) from zero to 20ppm H2S < 25 Zero current ppm equivalent in zero air < 0.3 Resolution RMS noise (ppm equivalent) < 0.05 Range ppm H2Slimit of performance warranty 100 Linearity ppm error at full scale, linear at zero and 20ppm H2S 0 to - 4 Overgas range |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:5NFL Place of Origin:UK ...Range NO Nitric Oxide Gas Sensor 4 Electrode Electrochemical The purpose of this document is to present the performance specification of the 5NFL nitric oxide gas sensor Datasheet: T90 Response Time < 30 seconds Baseline Offset 0 to +3 ppm equivalent Maximum Zero Shift 6 ppm... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:HF 3E 10 SE-4CTL Place of Origin:Britain ... Company adopts a three-electrode measurement principle. Besides the traditional sensing electrode and the negative electrode forming the structure of the fuel cell together, by measuring the current generated when the fluorine hydride gas undergoes a |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:FC-H2-5000 Place of Origin:CHINA ...Gas Sensor Is Used In Portable Gas Detection Instruments Features: Main parameters of the FC-H2-5000 hydrogen sensor are as follows: Core parameters Detection range: 0 - 5000 ppm (can be extended to 10000 ppm) Detection limit: 5 ppm Response time: < 60 seconds (±3% FS) Detection accuracy: ±3% FS (linear output) Sensitivity: 0.4 ± 0.2 nA/ppm Operating temperature range... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:4H2S-AS ...Gas Sensor (P/N: 114-020-120) Electrical property: Resolution 0.1ppm Bias 0 mV (none) Recommended resistance 5-30Ω Physical property: Weight 5 g Azimuth requirement None Working environment: Intended use for most life safety detectors Operating temperature range -40 to 50°C Operating pressure range 800-1200 mbar Operating humidity range... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:Membrapor Model Number:ALC/M-200 Place of Origin:Switzerland ...Process Control Operation Principle 3-Electrode Electrochemical Nominal Range 0 - 200 ppm Maximum Overload 400 ppm Output Signal Methanol: 1100 ± 400 nAppm Ethanol: 1000 ± 400 nAppm Resolution (Electronics dependent) < 0.05 ppm T90 Response Time < 30 s |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:A3STF Place of Origin:UK ...Gas Sensor Low Operating Humidity for Industrial Environments Specifications are valid at 20°c, 50% RH and 1013 mBar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time. Operating Principle 4-electrode electrochemical Measurement Range 0-10 ppm SO2 Maximum Overload 100 ppm |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:DDS Model Number:AQ+7NO2 Place of Origin:UK ...Gas Sensors 4th Electrode Environment Air Quality High Precision Detailed description: AQ+7NO2 is a 7-series format nitrogen dioxide sensor equipped with a 4-pin interface. AQ+7NO2 requires a 0V bias voltage. AQ+7NO2 has a measurement range of 0 - 20 ppm, an output current of 400 ± 100 nA/ppm... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:DDS Model Number:AQ-7O3 Place of Origin:UK ...Gas Sensors 7Series 4 Electrode Environment Air Quality High Precision Key Features: 1. Air Quality Specification, PPB 2. 4th electrode for improved baseline v temperature performance Detailed Description: AQ+7O3 O3 is a 7-series specification ozone sensor with a 4-pin interface. AQ+7O3 requires 0V bias voltage. AQ+7O3 has a measurement range of 0 - 1 ppm, an output current of 1700 ± 400 nA/ppm... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:ECO-SURE Place of Origin:USA Brand Name:Hpneywell ...Gas CO Carbon Monoxide Sensors Long Life Sensor Designed For Residential ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Features: 1. Long Life 2. Stable Performance 3. UL Certified - UL2075 ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Applications: Residential Fire Detection Ventilation Control Technical Specifications: Sensitivity Banding A : 30.0 - 35.9 nA/ppm B : 36.0 - 42.9 nA/ppm C : 43.0 - 50.9 nA/ppm D : 51.0 - 60.0 nA/ppm |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:Membrapor Model Number:CO/CF-1000 Place of Origin:Switzerland ... Nominal Range 0 - 1000 ppm Maximum Overload 2000 ppm Inboard Filter To remove acidic gases Output Signal 100 ± 20 nA/ppm Resolution (Electronics dependent) < 0.5 ppm T90 Response Time < 40 s Typical Baseline Range (pure air, 20°C) -2.0 ppm to 3.0 |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:EC Place of Origin:China Model Number:ES4-CH4S-100 ...Gas Sensor Short Warm Up Time Quick response • Low noise • No electrolyte leakage • Low cost for high volume • Extremely linear response at high concentrations • Individual calibration including test report Datasheet: Lower Detectable Limit (LDL) ≤ 1 ppm Resolution (16Bit ADC) 0.1 ppm Maximum overload 200 ppm Linear range 100 ppm Temperature Range -40 to 50 °C Humidity Range... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:4SO2-20 CLE-0421-400 Place of Origin:USA ...Gas Sensor For Detecting Concentration SO2 Air Features: Brand of 4so2-20 sulfur dioxide sensor: RAE Output: - Range: 0-20 PPM Product no. : cse-0421-400 Response time: T90≤45 seconds Resolution: 0.1 PPM Sensitivity: 0.5±0.1 A/ PPM Maximum detected concentration: 150ppm Normal detection range: 0-20ppm Operating temperature range: -20℃ ~ 50℃ Type: electrochemical gas |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |