Sign In | Join Free | My chinaqualitylighting.com |
|
All 60a current transformer core wholesalers & 60a current transformer core manufacturers come from members. We doesn't provide 60a current transformer core products or service, please contact them directly and verify their companies info carefully.
Total 17819 products from 60a current transformer core Manufactures & Suppliers |
|
![]() |
Brand Name:GFUVE Model Number:LZCK-55 Place of Origin:BEIJING CHINA ... or current levels. The most common usage of current transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:WSD Model Number:WSD-ZCT208 Place of Origin:CHINA ...current transformer 4-20ma ZCT Zero Phase Current Transformer Rated current : 30A Rated Output :10~12.5 mV Operating frequncy : 50Hz/60Hz Dielectric withstanding voltage(Hi-pot): 2500Vrms (between outside/sec.) Accuracy(0.1A-60A): linearity:0.5% DC resistance: 40+4 ohms APPLICATIONS - Residual current... |
Jiaxing Wisdom Electronic Tech Co., Ltd.
Zhejiang |
![]() |
Brand Name:WSD Model Number:WSD-ZCT212 Place of Origin:CHINA ...current transformer 4-20ma ZCT Zero Phase Current Transformer Rated current : 30A Rated Output :10~12.5 mV Operating frequncy : 50Hz/60Hz Dielectric withstanding voltage(Hi-pot): 2500Vrms (between outside/sec.) Accuracy(0.1A-60A): linearity:0.5% DC resistance: 40+4 ohms APPLICATIONS - Residual current... |
Jiaxing Wisdom Electronic Tech Co., Ltd.
Zhejiang |
![]() |
Brand Name:WSD Model Number:WSD-ZCT528 Place of Origin:CHINA ...current transforme 15A PCB Layout Current Transformer 1.5~2.0V PIN type Item No. :WSD-ZCT528 Rated current : 15A Rated Output :1.5~2.0V Operating frequncy : 50Hz/60Hz Dielectric withstanding voltage(Hi-pot): 2500Vrms (between outside/sec.) Accuracy(0.1A-60A): linearity:0.5% DC resistance: 57±5Ω APPLICATIONS - Residual current... |
Jiaxing Wisdom Electronic Tech Co., Ltd.
Zhejiang |
![]() |
Brand Name:YOMIN Model Number:YM-SCT-0750/1250/2000/3000 Place of Origin:Zhejiang , China ( Mainland ) ... split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easy and portable current measurement. |
YUEQING YOMIN ELECTRIC CO., LTD
Zhejiang |
![]() |
Brand Name:HNMC Model Number:SKH60 Place of Origin:China Split Core Current Transformer SKH60 Weatherproof Outdoor Split-core Current Transformer IP68 0.5 Power Distribution line monitoring Features & Technical Parameters Characteristic apply to copper row test on line Current range 600-2000A Accuracy class 0.5 ... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
![]() |
Brand Name:HNMC Model Number:SKH60 Place of Origin:China Split Core Current Transformer SKH60 Weatherproof Outdoor Split-core Current Transformer IP68 0.5 Power Distribution line monitoring Features & Technical Parameters Characteristic apply to copper row test on line Current range 600-2000A Accuracy class 0.5 ... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
![]() |
Brand Name:Shinhom Model Number:SCTK663 Series Place of Origin:China ...growing demand of installation into existing networks. Our split core current transformer can be a savings overall in the labor cost savings.Simply clip these around the wires being read. Secure them in place with a zip tie, without disconnecting cables or |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
![]() |
Brand Name:Chuangyin Model Number:CY-KCT01A-16 Place of Origin:ShenZhen ...dismantling the primary busbar or cables. They output 5A or 1A standard secondary currents which can directly match the input terminals of electric energy meter and measure and control instruments in power system. They are applied to electric measure and |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:Chuangyin Model Number:CY-KCT03 Place of Origin:ShenZhen ...Core Current Transformer / Open type CY-KCT03 1.Product Introduction: The "KCT03" Split Core Current Transformers" are designed for easy installed without the need for dismantling the primary busbar or cables. They output 5A or 1A standard secondary currents... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:GFUVE Model Number:LZCK-55, 100/5A Place of Origin:BEIJING CHINA ...the power system. Split core cTs are used at generating stations, electrical substations, and in industrial and commercial electric power distribution. LZCK-55 waterproof outdoor split core current transformers are applicable for AC power system 35kV and |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:Chuangyin Model Number:CY-FLXK-XX Place of Origin:ShenZhen 100A 50/60Hz Sensor Split Core Current Transformer DC/AC Current Transformer Introduction: CY-FLXK-XX Flexible Steel Strips Zero-Sequence Current Transformer is specially designed for assembling and disconnecting the existing main busbar or cable ... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:Acrel Model Number:AKH-0.66 Place of Origin:Jiangsu, China ...: 720V AC ● Test voltage: 3kV AC(1min) ● Rated frequency: 50/60Hz ● Rated short-time thermal current: Ith=40~60In ● Rated dynamic current: Idyn=2.5Ith ● Rated secondary current: X/5A (X/1A upon request) ● |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
![]() |
Brand Name:Acrel Model Number:AKH-0.66/K-Φ Place of Origin:China ... ct split core current sensor General Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment. ... |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
![]() |
Brand Name:Acrel Model Number:AKH-0.66-K-24 150-300A/5A Place of Origin:China ... appearance, convenient installation split core and wiring, mainly used in power operations and electricity reconstruction projects. Split Core Type current transformers can be easily installed onto an existing power system without disconnecting the |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
![]() |
Brand Name:Shinhom Model Number:SCTK662 Series Place of Origin:China ...Core Current Transformer High Accuracy CT, 5-3000A input SCTK662 series of split-core current transformer offers 0V-10V and 0mA-500mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect SCTK662 series to meter for high accuracy metering application. It enables one meter to be adopted for various current... |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
![]() |
Brand Name:Shinhom Model Number:ACST Series Place of Origin:China ...Current Transformer,High Accuracy Split core current transformer are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easier and portable current... |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |