| Sign In | Join Free | My chinaqualitylighting.com |
|
All buy o2 sensor wholesalers & buy o2 sensor manufacturers come from members. We doesn't provide buy o2 sensor products or service, please contact them directly and verify their companies info carefully.
| Total 1918 products from buy o2 sensor Manufactures & Suppliers |
|
|
|
Brand Name:WEILI Model Number:WL03-0215 Place of Origin:China 90919-02258 90919-02252 Auto Car Ignition Coil for Toyota COROLLA bobina de encendido 1: Quick Details Model: COROLLA, MATRIX (_E14_), PRIUS (_W3_), PRIUS PLUS (_W4_) Engine: 1.8, 1.8 Hybrid (ZVW4_), 1.8 Hybrid (ZVW3_), 1.8 (ZRE142_) Year: 2001-2005, 2009... |
Guangzhou Yu Meng Yang Automotive Components Co., Ltd.
Guangdong |
|
|
Place of Origin:China Brand Name:Longyue autoparts ... THAT RELOCATE YOUR O2 SENSOR. -ALSO GREAT FOR MOTOR SWAP WHERE YOU FACTORY HARNESS DON'T REACH THE NEW O2 SENSOR LOCATION. -DON'T CUT UP AND ADD WIRES YOUR O2 SENSOR TRYING TO RIG IT, AS DOING SO MAY CAUSE FAULTY CONNECTION AND DAMAGE THE SENSOR(VERY |
Ruian Longyue electronics co.,ltd
Zhejiang |
|
|
Brand Name:MEDKE Model Number:VB0035 Place of Origin:CHINA ... Range: 0 – 100% vol. O2, 0 to 1500 mBar O2 This oxygen sensor is available for use with Criticare: 8100 Poet, 8500 Poet; Datex Ohmeda: Centiva S/5; Draeger > Air Shields: Isolette 8000; ... |
Shenzhen Medke Technology Co., Ltd.
Guangdong |
|
|
Brand Name:MEDKE Model Number:VB0035 Place of Origin:CHINA ... Range: 0 – 100% vol. O2, 0 to 1500 mBar O2 This oxygen sensor is available for use with Criticare: 8100 Poet, 8500 Poet; Datex Ohmeda: Centiva S/5; Draeger > Air Shields: Isolette 8000; ... |
Shenzhen Medke Technology Co., Ltd.
Guangdong |
|
|
Brand Name:MEDKE Model Number:VB0035 Place of Origin:CHINA ... Range: 0 – 100% vol. O2, 0 to 1500 mBar O2 This oxygen sensor is available for use with Criticare: 8100 Poet, 8500 Poet; Datex Ohmeda: Centiva S/5; Draeger > Air Shields: Isolette 8000; ... |
Shenzhen Medke Technology Co., Ltd.
Guangdong |
|
|
Brand Name:Alphasense Model Number:O2-A2 SR-X10-C1 Place of Origin:UK O2-A2 SR-X10-C1 Gas O2 Sensor About 16g Resopnd Time 90s Under 15 PERFORMANCE Output µA @ 20.9% O2 80 to 120 Response time t90 (s) from 20.9% to 0% O2 < 15 Zero current µA in N2 < 2 Linearity % O2 deviation @ 10% O2 0.6 LIFETIME Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% O2 > 24 ENVIRONMENTAL Humidity Sensitivity % O2 change: 0% to 95% rh @ 40°C < 0.7 CO2 sensitivity % (change O2 |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:City Technology Model Number:MOX-3 Place of Origin:UK ...sensor MOX-3 O2 cell with Data socket Description of Oxygen sensor: The Citytech MOX-3 O2 sensor, a vital component designed for use in various medical equipment applications. This high-quality sensor is engineered to provide accurate and reliable oxygen level measurements, ensuring optimal performance in critical healthcare settings. Specification of Oxygen sensor: Output Voltage 9-13mV Measurement range 0 to 100% O2 |
Precise life group limited
Guangdong |
|
|
Brand Name:Med Accessories Model Number:MOX4 Place of Origin:China ...Sensor Medical,Practical MOX4 Oxygen Sensor MOX4 OXYGEN SENSOR O2 sensor.pdf Operating Principle Partial pressure electrochemical Output 9 mV to 13 mV in 210 mBar O2 Measurement Range 0 mBar to 1500 mBar O2 Response Time <15 s (air to 100% O2 ) Baseline Offset <200 μV Linearity Linear 0% to 100% O2... |
Med Accessories Technology Dongguan Co., Ltd.
Guangdong |
|
|
Brand Name:Pray-med Model Number:PSR-11-75-KE4 Place of Origin:USA Original SR 11 75 KE4 Medical Oxygen Sensor O2 Cell CE Approvaled Product Description PSR-11-75-KE4 O2 cell Original oxygen sensor O2 sensor Measuring Range 0-100% Accuracy +/-2% of Full Scale Linearity +/-2% of Full Scale Signal output 10-14mV Temp ... |
Shenzhen Pray-med Technology Co.,Ltd
Guangdong |
|
|
Brand Name:MEDKE Model Number:FY002 Place of Origin:CHINA ...O2 Cell OOM202 Envitec Oxygen Sensor Medical For Draeger Original O2 Cell OOM202 Envitec Medical Oxygen Sensor for Draeger Features: Envitec OOM202 Medical oxygen sensor , Compatible OOM202 O2 CELL Replacement: Analytical Industries PSR-11-915-2 City Technology MOX-16 Drager 6850645 Hamilton HM-13,HM-14 Ohmeda O2... |
Shenzhen Medke Technology Co., Ltd.
Guangdong |
|
|
Brand Name:GE Model Number:MLF-19GE Place of Origin:USA ...O2 Oxygen Sensor Use For CPAP Machines Lead Free A wide range of LEAD-FREE Galvanic Oxygen Sensor as a direct replacement with major Anesthesia machines, Respiratory ventilators, Incubators, CPAP machines and other O2 Therapy units available in market. Supreme performances and outstanding longevity from the NEW patented LEAD-FREE Galvanic O2 sensor... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:envitec Model Number:oom201 Place of Origin:france ... battery is mainly compatible with Dräger 6850645 oxygen battery Product Description: O2 Sens Medical Oxygen Sensor Main function: monitoring inhaled oxygen concentration in anesthesia breathing equipment Performance parameters: electrochemical principle; |
Shenzhen Pray-med Technology Co.,Ltd
Guangdong |
|
|
Brand Name:SGX Model Number:SGX-VOX Place of Origin:UK ...Sensor 5s Response For Medical Instruments Breath Machine Oxygen Sensor For Medical Instruments O2 Sensor SGX-VOX Features: SGX Sensortech SGX-Vox Oxygen Sensor for ventilators is a 0% to 100% oxygen (O2) sensor with onboard temperature compensation. The oxygen sensor has < in air (measured at standard pressure and temperature); Zero current (offset) of 0.1% O2... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:Bacharach Model Number:0024-0788 Place of Origin:- ...O2 sensor is used in Bacharach portable combustion analyzers to measure the percentage content of oxygen levels in flue gases. The range of the oxygen sensor is 0 – 20.9%. O2 measurement is used in conjunction with the chosen fuel to calculate the CO2 levels in flue gases. Bacharach portable combustion analyzers only calculate CO2 when oxygen levels are below 16%. Bacharach uses O2... |
Mengchuan Instrument Co,Ltd.
Zhejiang |
|
|
Brand Name:Envitec Model Number:OOM110 Place of Origin:germany ... sensor o2 cell for envitec product description: GE datex ohmeda 6050-0004-110 Oxygen sensor o2 sensor City technology mox-7,mox-07 IT-gambert m-10 Maxtec max-10 Ohmeda aestiva,7900 monitor,excel se6050-0004-110 Condition:brand new This oxygen sensor is ... |
Shenzhen Pray-med Technology Co.,Ltd
Guangdong |
|
|
Brand Name:DD Scientific Model Number:S+VOX Place of Origin:UK ...sensor for Aeonmed VG70 ventilator Introduction of medical oxygen sensor: The S+VOX is a partial pressure O2 sensor with linear output from 0-100%O2, optimised for ventilators Features of medical oxygen sensor: * Fast response, * 0-100% measurement range, * on-board temperature compensation, * low drift. Performance Characteristics of medical oxygen sensor: Output signal 9-13mV in Air @STP Zero Current (Offset) < 0.1%O2 |
Precise life group limited
Guangdong |
|
|
Brand Name:RAE Model Number:022-0902-000 4O2-LQ Place of Origin:UK ...Sensor Detections in Industrial Applications The ‘LQ’ version O2 sensor is a unique design of high performance electrochemical gas sensor utilising standard liquid electrolyte. A 3-electrode advanced sensor offering high stability. Measuring Range: 0 – 30% vol. O2 Size: 4 SERIES version Part no: 2112B0231400 (CLE-0231-400) Speficication: Operating Principle Electrochemical, 3 electrode cell Gas Detected Oxygen O2 |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Place of Origin:China Brand Name:Med Accessories Model Number:OOM204 ...O2 Cell OOM204 Envitec Medical O2 Sensor For Draeger Measurement range :0 % ... 100 % oxygen (at atmospheric pressure) Nominal sensor lifetime: ≥ 500 000 % volume oxygen hours Output in ambient air: 14 mV ... 20.7 mV (Dual Cathode), load 600 Ohms Electrical interface: Gold plated slip rings Accuracy meets: ISO 80601-2-55 requirements Repeatability: < 1 % volume O2... |
Med Accessories Technology Dongguan Co., Ltd.
Guangdong |
|
|
Brand Name:Med Accessories Model Number:Hamilton oxygen sensor Place of Origin:China 396200/3962001 Original C2 C3 C6 Hamilton Oxygen sensor/O2 cell O2 sensor.pdf Product Description Output Signal 13-16mV Measurement range 0 to 100% O2 Output connector Molex 3 pin Accuracy With +/- 1% of full scale Response time <12 seconds Operating ... |
Med Accessories Technology Dongguan Co., Ltd.
Guangdong |