Brand Name:KACISE Model Number:KMF-Series Place of Origin:Shaanxi, China (Mainland) ...Density Meters For Liquid Density Mass Flow Meter Product Description DN150mm Coriolis mass flow meter directly measures the "Mass" of the Medium with high accuracy based on the Coriolis Principle (Coriolis Force). The accuracy would not be affected by any factors like the temperature, pressure, density, viscosity,etc. And the compensation calculation is not required. The Coriolis Mass Flow Meter... |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |
|
|
Model Number:LUGBML Place of Origin:China ...Flow Meter with DN25 - DN300 Pipeline Diameter 1. Introduction LUGBML series Vortex Flow Meter sensor can be used to detect and measure the flow of all kinds of gas, liquid and steam. LUGBML series Vortex Flow Meter can be used to match with our company’s ML6000 series Velocity Flowmeter. It can also match with a computer and sensors of temperature, pressure, or density to compose high accuracy mass flow or heat flow |
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
Shanghai |
|
|
Place of Origin:Anhui, China Brand Name:WNK Model Number:WLD ... by changes in fluid density, viscosity, temperature, pressure and conductivity; - Unobstructed flow components in the measuring tube, no pressure loss, low requirements for straight pipe sections; - Series nominal diameter DN3-DN3000. There are many |
Hefei WNK Smart Technology Co.,Ltd
Anhui |
|
|
Brand Name:Iflow Model Number:EMF-80-2 Place of Origin:China ...flow meter in water utilities flow monitoring, Power: AC or DC, Modbus RS485, GPRS Introduction: The newly introduced primary flow sensor and flow transmitter, are applied in our electromagnetic flow meter. It works on Faraday's lway of electromagnetic induction. This flow meter is for volumetric flow measurement. The flow measurement is independent of viscosity, density... |
Shanghai I Fluid Technology Co., Ltd.
Shanghai |
|
|
Brand Name:YUNYI Model Number:YFGR50 Place of Origin:China ... gas, coal gas, air) and liquid (such as oil, chemical liquid), with an accuracy of ±0.5% to ±1%, and some models can reach ±0.2%. Not affected by changes in fluid density and viscosity, strong stability. 2. Wide range ratio The range ratio is usually 1 |
Xi'an Yunyi Instrument Co., Ltd
|
|
|
Brand Name:VACORDA Model Number:HKLD Place of Origin:Sichuan, China (Mainland) ...Flow Meter Electromagnetic Flow Meter Display Convertor The electromagnetic method measures the volume flow, which means the measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic flow meter... |
Sichuan Vacorda Instruments Manufacturing Co., Ltd
Sichuan |
|
|
Brand Name:Atech sensor Model Number:PL806 Place of Origin:China ...measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic water flow sensor measurement transmitter meters is calibrated with water, it can be used to measure the other types of |
Atech sensor Co.,Ltd
Shaanxi |
|
|
Brand Name:Micro motion Model Number:F025 F050 F100 Place of Origin:Mexico ...FLOW METER 1/2" F050S113CRAAEZZZZ F025 F050 F100 Micro Motion F-Series Coriolis Meter Consisting of F050S Sensor and 5700 Transmitter Features Achieve highly accurate mass volume flow and density measurement in applications that require a compact, drainable design Available in 316L Stainless Steel and C-22 nickel alloy Improve measurement and tracking with extensive process and meter... |
Mengchuan Instrument Co,Ltd.
Zhejiang |
|
|
Brand Name:Purescience Model Number:YF-F80 Place of Origin:China ...flow meters by magnetic flowmeter, PTFE liner, remote display, PN16 Product Description The electromagnetic flow meter, sizes from 1 to 24 inches. It has no parts to obstruct flow resulting in no pressure loss and the 0.75% accuracy is not affected by temperature, pressure, viscosity, density or flow... |
Shanghai Xunhui Environment Technology Co., Ltd.
Shanghai |
|
|
Brand Name:VOTESEN Model Number:VMG600 Place of Origin:CHINA ... loss or jamming. 2. Measurement is free from series of influences e.g medium density,elasticity ,temperature or electrical conductivity. 3. Corrosion resistance and wearability standard among other indexes are met via selecting different materials for |
Xian Votesen Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:WNK Model Number:WLD Place of Origin:China ...Flow Meter Electromagnetic Flow Sensor Product Description WLD electromagnetic flowmeters is manufactured with the latest technology with the following features: 1) Measurements are not affected by changes in fluid density, viscosity, temperature, pressure anf conductivity. 2) Unobstructed flow... |
Hefei WNK Smart Technology Co.,Ltd
Anhui |
|
|
Brand Name:NUOYINGJIAYE Model Number:NYLL-CH Place of Origin:China ... intelligent flowmeter developed by our company based on Faraday electromagnetic induction principle. Large measurement range, measurement is not affected by temperature, density, pressure, |
Xi'an Dehou Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:HUIYUE Place of Origin:CHINA ...Flow Meter adopts new type of external clamp design, which can obtain the flow contacting the measured medium. Due to the advantages of the clamp-on flow meter, it is not necessary to cut off the pipeline or stop the equipment for a long time, saving cost and labor cost. The ultrasonic flow meter is simple and quick to install and operate, and the flow... |
Zhuhai Huiyue Technology Co., Ltd
Guangdong |
|
|
Place of Origin:Shanghai, China (Mainland) Brand Name:Lanry Model Number:TF1100-EH ..., level and flow totalizer. The built-in digital memory makes sure that the data will not lose in case of power failure. The portable Ultrasonic flow meter TF1100-CH works on the transit-time principle. The clamp-on ultrasonic sensors are mounted on |
Lanry Instruments (Shanghai) Co., Ltd.
Shanghai |
|
|
Brand Name:NNT Model Number:NPF2A7 Place of Origin:China ...flow is too high or too low or even protect a pump. The flow sensor will usually send an electrical signal to a PLC or other electronic controller How do I choose a flow switch? To choose the best sensor (flow detector) for your application, you should be |
Guangdong Nuonengtai Automation Technology Co., Ltd.
Guangdong |
|
|
Place of Origin:Shanghai, China Brand Name:COWELL/OEM Model Number:K24 ...Flow Meter for Adblue & Chemicals Description The K24 AdBlue Digital Flow Meter from is a reliable and accurate turbine flow meter for the dispensing of urea and cattle milk (not for human consumption). This AdBlue flow meter has a digital face that can rotated 90 degrees, providing the user with the benefit of easy reading. This is the flow meter used in the metered... |
Shanghai Cowell Machinery Co., Ltd.
Shanghai |
|
|
Brand Name:ABB Model Number:FSV450 ...meter for high end flow applications. It uses a two-wire transmitter with leading edge DSP-technology with enhanced flow computer functionality. Signals from remote sensors like pressure, temperature, density or gas content can be read in by an integrated analog 4 ... 20 mA interface and computed directly with the flow... |
Eco-Tech Suzhou Limited
|
|
|
Brand Name:HIGHLAND Model Number:MYHT-1-4 Place of Origin:China Dezhou ... 420 Bar, our flow meters are designed to provide reliable and accurate readings. Highland Hydraulic Flow Meters feature an oil temperature range from -20℃ to 150℃, providing a wide range of applications for various industries. Our flow meters are also |
Shandong Highland Hydraulic Seiko Co., Ltd.
Shandong |
|
|
Model Number:8705 Place of Origin:Singapore ...Flow Measurement Solution 8705 Magmeter Flow Meter Product Description: The Smart Digital Flow Measurement Solution 8705 Magmeter Flow Meter is a high-precision electromagnetic flow meter designed for reliable liquid measurement in industrial applications. Utilizing advanced digital signal processing, it ensures accurate flow... |
Shaanxi Huibo Electromechanical Technology Co., Ltd
Shaanxi |
|
|
Brand Name:HCH-005 Model Number:0281002309 Place of Origin:CHINA ...: 1. product name:air flow meter 2. RELATIVE NO.:0281002309 3. OEM NO:46559804 55193048 60816137 465598040 3. suitable for fiat alfa 4. item condition:new 5. package method:... |
RUIAN HONGCHUANG CAR FITTINGS CO.,LTD