Sign In | Join Free | My chinaqualitylighting.com |
|
All fast response ch4 gas sensor wholesalers & fast response ch4 gas sensor manufacturers come from members. We doesn't provide fast response ch4 gas sensor products or service, please contact them directly and verify their companies info carefully.
Total 2522 products from fast response ch4 gas sensor Manufactures & Suppliers |
|
![]() |
Brand Name:Membrapor Model Number:CO/CF-1000 Place of Origin:Switzerland ... Filter To remove acidic gases Output Signal 100 ± 20 nA/ppm Resolution (Electronics dependent) < 0.5 ppm T90 Response Time < 40 s Typical Baseline Range (pure air, 20°C) -2.0 ppm to 3.0 |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:4H AC200-800 Place of Origin:USA ... H2S Gas Sensor Low Detection For Industrial Applications Specification: Operating Principle 3-electrode electrochemical Measurement Range 0-100 ppm Maximum Overload 500 ppm Resolution 0.1PPM Filte None Sensitivity 1.20 ± 0.25 µAppm Response Time < 30... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:YJJ Model Number:4OL CLE-0231-400 Place of Origin:USA ...400 Oxygen Gas Sensors 0-30% Vol New Style Performance Characteristics Part Number CLE-0231-400 Nominal Range 0 to 30% O2 Maximum Overload 90% O2 Output Signal -350 ± 50 μA in air Zero Signal -40 ~ 10 μA in Nitrogen Resolution 0.1% O2 Response Time (T90... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Model Number:4OX-V 4OXV module ...module Oxygen (O2) Gas Sensor module Part Number: AAY80-390 False alarm immunity Key Features and Benefits: • False alarm immunity • Reliably meets stated life • Superior environmental performance • Enhanced response time in extreme applications ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:RAE Model Number:4O2-LQ CLE-0231-400 Place of Origin:Britain ... 0 to 30% O2 Electrochemical Oxygen Gas Sensor Features: Product Model: CLE-0231-400 Range: 0 to 30% O2 Maximum load: 90% O2 Output signal: -350 ±50 μA in air Baseline: -40 ~ 10 μA (nitrogen) Resolution: 0.1% O2 Response time (T90) : ≤ 30 seconds ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:3CO-500 CLE-0052-300 Place of Origin:Britain ... Carbon Monoxide CO Gas Sensor Features: Product Model: CLE-0052-300 Range: 0-500 ppm Maximum load: 1500 ppm Sensitivity: 0.08 +0.02uAVppm Baseline (20℃) : < ±0.2 μA Baseline drift: equivalent to 0to3ppm CO Resolution: 1 ppm Response time (T90) ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:3EF 3E/ F AB004-J08 Place of Origin:Britain ...Gas Sensor 3EF 3E/ F AB004-J08 Features: Nominal Range :0-1000ppm Maximum Overload:2000ppm Expected Operating Life:Three years in air Output Signal:0.10 ± 0.02 µA/ppm Inboard Filter (3E/F only):To remove SOx/NOx & H2S Resolution:0.5ppm Temperature Range:-20°C to +50°C Pressure Range:Atmospheric ± 10% Pressure Coefficient:0.020 ± 0.008 %signal/mBar T90 Response... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:3H2S-100 CLE-0112-300 Place of Origin:Britain ... Sulfide H2S Gas Sensor Features: Product model CLE-0112-300 Measuring range 0-100 ppm Maximum load 500 ppm Sensitivity 0.8 ± 0.2uAppm Baseline (20°C) : < +0.4 μA Baseline drift: equivalent to 0 to 0.2 ppm H2S Resolution 1 ppm Response time (T90) ≤... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:3HHLM AC005-J00 Place of Origin:Britain ...Electrochemical Hydrogen Sulfide (H2S) Gas Sensor Features: MEASUREMENT Operating Principle:3-electrode electrochemical Measurement Range:0-50 ppm H2S Maximum Overload:500 ppm H2S Filter:None Sensitivity:1.70 ± 0.30 μA/ppm Response Time (T90):<30 Seconds... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:4CFC 2112B2006 Place of Origin:Britain ...Gas Sensor Part Number: 2112B2006 Features: Nominal Range 0-1000 ppm CO Maximum Overload 2000 ppm CO Inboard Filter To remove H2S Expected Operating Life Two years in air Output Signal 0.37 ± 0.07 µA/ppm Resolution 0.5ppm Temperature Range -20° to +50°C Pressure Range Atmospheric ± 10% Pressure Coefficient 0.015 % signal/mBar T90 Response... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:4CL2-50 CLE-0951-400 Place of Origin:Britain ...Gas Sensor Used For Chlorine Leakage Monitoring In Chemical Pharmaceutical Plants And Other Places Features: Product model CLE-0951-400 Range 0 to 50 ppm Load 100 ppm Sensitivity 0.45 ± 0.20 mA/ppm Baseline (20℃) <± 0.1 ma Baseline drift is equivalent to 0 to 0.3 ppm (-20 to 40 ℃) Resolution 0.1ppm Response... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:CITY Model Number:4SPE O2 CLE-0231-40S Place of Origin:Britain ...Concentration Monitoring Gas Sensor Features: Product model CLE-0231-40S Range 0 to 30% O2 Load 100 ppmSensitivity 1.4 ± 0.6 mA/ppm Baseline (20℃) <± 0.4 mA Baseline drift is equivalent to 0 to 0.5 ppm (-20 to 40℃)Resolution 0.1ppm Response time (T90... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Model Number:4OL CLE-0231-400 Place of Origin:USA ...CLE-0231-400 O2 Electrochemical Gas Sensor Oxygen Detector Features: Product type CLE-0231-400 Measuring range 0 to 30% O2 Load 90% O2 Output signal 350 ± 50 μA in air Baseline <20 μa (nitrogen) Resolution 0.1% O2 Response time (T90) £30 seconds ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Model Number:CS2/CF-100 CS2/CF-500 ...Gas Sensor Highly Selective And Sensitive CS2 Detection For Discontinuous Measurement Key Features: • Highly selective and sensitive CS2 detection • Ideal for TLV-TWA level measurements Applications: • Discontinuous Measurement • Safety and Process Control T90 Response... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Model Number:H2/CA-1000 Place of Origin:Switzerland ...Gas Sensor For Medical Applications Key Features : Highly selective H2 detection in presence of CO Applications: • Medical Applications • H2 Detection in H2/CO-Mixtures • Medical Applications Nominal Range 0 - 1000 ppm Maximum Overload 2000 ppm Inboard Filter To remove CO Output Signal 28 ± 11 nA/ppm 1) Resolution (Electronics dependent) < 1.8 ppm T90 Response... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:YJJ Model Number:4HS/LM AC226-800 Place of Origin:USA ...Gas Sensor Is Used For H2S Concentration Detection Features: Performance Characteristics Nominal Range:0-100 ppm Maximum Overload:500 ppm Expected Operating Life:Two years in air Output Signal:0.70 ± 0.15 μA/ppm Resolution:0.1 ppm Temperature Range:-40°C to +50°C Pressure Range:Atmospheric ± 10% Pressure Coeffi cient:No data T90 Response... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:SG Model Number:Hall Effect Current Sensor Place of Origin:Dongguan China ... (direct) and closed loop (magnetic balance). The advantage of the direct-amplification Hall sensor is that the circuit form is simple and the cost is relatively low; the disadvantage is that the accuracy and linearity are poor, the response time is slow, |
Dongguan Chenglue Electronic co.,Ltd
Guangdong |
![]() |
Brand Name:YuanTe Model Number:SKY2000-F2 Place of Origin:China Portable High Precision And Fast Response 0-1ppm Range F2 Fluorine Toxic Gas Detector With USB Port Specifications Gas Detected F2/Fluorine Detection principle Electrochemistry Sampling Method Pumping suction, flow rate can up to 1L/min, ten grades of ... |
Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Guangdong |
![]() |
Brand Name:SAFEGAS Model Number:SKY2000 Place of Origin:China ..., which ensures the response time of the detector. Unique design, small size and convenient transportation. High-strength special engineering plastic shell is suitable for ... |
Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Guangdong |
![]() |
Place of Origin:Dongguan,Guangdong,China Brand Name:UCHI Model Number:HAS ...Sensor High Sensitivity And Fast Response Quick detais •With whole new technology, securing stable performance in long time(annual resistance drift rate ≤1‰). •Resistance and B value in high precision, with good consistency and interchangeability (precision of resistance and B value reach ±1 % respectively). •High sensitivity and fast response... |
Guangdong Uchi Electronics Co.,Ltd
Guangdong |