| Sign In | Join Free | My chinaqualitylighting.com |
|
All fluorescence analysis do sensor wholesalers & fluorescence analysis do sensor manufacturers come from members. We doesn't provide fluorescence analysis do sensor products or service, please contact them directly and verify their companies info carefully.
| Total 1853 products from fluorescence analysis do sensor Manufactures & Suppliers |
|
|
|
Brand Name:Desun Uniwill Model Number:DS-380 Place of Origin:China Online RS485 4-20mA Fluorescence Water Dissolved Oxygen Sensor for River Water Quality Monitoring In addition to aeration, other factors can affect DO levels in aquaculture systems. For example, the presence of excess organic matter, such as ... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
LH-DY06 Fluorescent Dissolved Oxygen Sensor Intelligent For Industrial Waste And Swimming Pool WaterBrand Name:HiYi Model Number:LH-DY06 Place of Origin:China ... to the sensor surface. The green light excites the luminescent material. As the material relaxes it emits red light. The time it takes for the red light to be emitted is measured. Between the flashes of blue light, a red LED is flashed on the sensor and |
Beijing HiYi Technology Co., Ltd
Beijing |
|
|
Brand Name:OEM/ODM Model Number:P1 Place of Origin:Guangdong, China Original P1 GPS ECG Detection HRV Analysis Smart Watch Fitness Tracker Heart Rate Monitor Multiple Sports Modes Smartwatch Why us? *Wearable device leader in China. *10,000,000+users all over the world. *90+professionals whith professional experiences. *... |
Frclink Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Brand Name:Daruifuno Model Number:OPD7 Place of Origin:China Fluorescence Digital Dissolved Oxygen Sensor For Thermal Power Plants The dissolved oxygen analyzer(DO controller and DO sensor) is widely used in industrial applications. For example, in thermal power plants, in order to inhibit the metal corrosion of ... |
Suzhou Delfino Environmental Technology Co., Ltd.
Jiangsu |
|
|
Brand Name:HEWEI Model Number:HW-ERI Place of Origin:China Fluorescent conjugated polymers, more than 8 hours working time, Handheld Explosive Detector Introduction: The new developed HW-ERI product is the portable explosive detector with the highest detection limit and the most explosives in the domestic and ... |
Beijing Heweiyongtai Sci & Tech Co., Ltd.
Beijing |
|
|
Brand Name:Desun Uniwill Model Number:DS-380 Place of Origin:China Digital Fish Farm Dissolved Oxygen Meter Fluorescent DO Senor with Temperature DO Meter for Water Why need to measure the dissolved oxygen? For aquaculture, if dissolved oxygen levels are too low, fish can suffocate and die as a result. In wastewater ... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:kacise Model Number:KFDO300 Place of Origin:CHINA ...online applications, utilizing the OSA optical water quality analysis platform. This integrated sensor incorporates advanced oxygen sensing technology through the fluorescence quenching method. It embraces a digital and intelligent sensor design concept, |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |
|
|
Brand Name:Desun Uniwill Model Number:DS-380 Place of Origin:China Fluorescence Analysis Dissolved Oxygen Sensor Probe 12V Titanium Features * 0-20mg/L or 0-200% saturation * 0~50 °C; *IP68 protection level * No film, no electrolyte, no polarization * No need to consume oxygen, no flow rate * Built-in temperature sensor, automatic temperature compensation Technical Parameters Item Parameters Model DS380 Principle Fluorescence analysis... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:Desun Uniwill Model Number:DS-380 Place of Origin:China ISO Fluorescence Optical Dissolved Oxygen Sensor 15 m for fish modbus protocol DS-380 Dissolved Oxygen(DO) Sensor design based on the principle of Fluorescence analysis method and high performance through oxygen membrane, with short response time, ... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:Desun Uniwill Model Number:DS-380 Place of Origin:China ...Sensor Optical fluoresce do probe Photos Technical Specifications Item Parameters Model DS380 Principle Fluorescence analysis method Measuring range 0~20mg/L or 0-200% saturation Response time 3 sec Accuracy 1% Protection level IP68 Installation Submersible Temperature sensor... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:Desun Uniwill Model Number:DS530 Place of Origin:China ... fluorescence analysis, has high sensitivity, and can detect soluble and emulsifiable oils. In addition, the self-cleaning brush version can be selected to effectively eliminate the influence of ... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:Desun Uniwill Model Number:DS305 Place of Origin:China ...Sensor Analysis for Water Quality Monitoring Features of blue-green algae sensors Fluorometers: Blue-green algae sensors often incorporate fluorometers, which use fluorescence to measure the concentration of blue-green algae. Fluorometers emit light at a specific wavelength, and when blue-green algae are present, they emit fluorescence... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:Daruifuno Model Number:MLSS31 Place of Origin:China ...Sensor with brush for Waste Treatment Fluorescent Sludge Concentration Sensor MLSS31 is a technology commonly used to measure sludge concentration in water bodies. It uses the fluorescence characteristics of specific substances in sludge for concentration analysis. Compared with other sensing technologies, fluorescence sensors have some advantages in specific application scenarios: High Sensitivity: Fluorescence |
Suzhou Delfino Environmental Technology Co., Ltd.
Jiangsu |
|
|
Brand Name:Daruifuno Model Number:COD351H Place of Origin:China ...Sensor For Industrial Process Monitoring UV fluorescence absorption method COD sensor COD351H (Chemical Oxygen Demand) is a technique commonly used in water quality monitoring and analysis. They measure COD and TOC content based on the ultraviolet (UV) absorption and fluorescence properties of organic substances in the sample. Advantage technology: Rapid analysis: UV fluorescence absorption COD and TOC sensors |
Suzhou Delfino Environmental Technology Co., Ltd.
Jiangsu |
|
|
Brand Name:Desun Uniwill Model Number:DS-380 Place of Origin:China ... and fast response. ● Immune to electrical interference, no chemical interference. Technical Specifications Item Parameters Model DS380 Principle Fluorescence analysis method Measuring range 0~20mg/L or 0-200% saturation Response time 3 sec Accuracy 1% |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:kacise Model Number:KOI300 Place of Origin:CHINA ...Sensor Water Quality Sensor Instrument Introduction KOI300 online oil in water sensor is an online water quality sensor based on OSA optical water quality analysis platform. In an integrated design, high brightness UV leds of a specific wavelength excite the Polycyclic aromatic hydrocarbon to make them fluoresce, and high sensitivity photoelectric sensors capture weak fluorescence... |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |
|
|
Brand Name:Desun Uniwill Model Number:DS530 Place of Origin:Shaanxi, China Online Crude Oil In Water Sensor Water Quality Sensor Online Oil In Water Sensor Product Description The oil in water sensor adopts the principle of ultraviolet fluorescence analysis, has high sensitivity, and can detect soluble and emulsifiable oils. In ... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:SKYLINE Place of Origin:CHINA ... total sulfur content is determined by ultraviolet fluorescence method, and the main part is imported, which makes the performance of the whole machine comparable to similar imported products. Instruments are widely used in petroleum and petrochemical, |
SKYLINE INSTRUMENTS CO.,LTD
Guangdong |
|
|
Brand Name:Desun Uniwill Model Number:DS-380 Place of Origin:China ...sensor 4-20 ma output 10 meter cable Factory price water quality sensor Technical Specifications Item Parameters Model DS380 Principle Fluorescence analysis method Measuring range 0~20mg/L or 0-200% saturation Response time 3 sec Accuracy 1% Protection level IP68 Installation Submersible Temperature sensor... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:KACISE Place of Origin:Shaanxi, China (Mainland) Model Number:KBU601 ...sensor Feature Digital sensor, RS-485 output, support MODBUS. Optional automatic cleaning brush to eliminate the impact of oil on the measurement, this product uses a unique optical and electronic filtering technology to eliminate the impact of ambient light on the measurement, not affected by suspended solids. Applications The oil sensor in the water uses the principle of ultraviolet fluorescence analysis... |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |