Sign In | Join Free | My chinaqualitylighting.com |
|
All ground fault circuit interrupter plug wholesalers & ground fault circuit interrupter plug manufacturers come from members. We doesn't provide ground fault circuit interrupter plug products or service, please contact them directly and verify their companies info carefully.
Total 374 products from ground fault circuit interrupter plug Manufactures & Suppliers |
|
![]() |
Brand Name:HAROK Model Number:GFST-1 Place of Origin:CHINA What is a GFCI Socket? The GFCI (Ground Fault Circuit Interrupter) socket is an electrical safety device that is designed to prevent electric shock by interrupting the circuit if there is an imbalance of electric current flow between the energized ... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:KRIPAL Model Number:UKB7LE Place of Origin:China ...Circuit Breaker 10mA 30mA 100mA 300mA Residual current breaker with over-current protection (RCBO) — combines the functions of an RCD and an MCB in one package. In the United States and Canada, panel-mounted devices that combine ground (earth) fault detection and over-current protection are called Ground Fault Interrupter (GFI) breakers; a wall mounted outlet device or separately enclosed plug... |
Zhejiang KRIPAL Electric Co., Ltd.
Zhejiang |
![]() |
Brand Name:KRIPAL Model Number:UKB7LE Place of Origin:China ...Circuit Breaker 10mA 30mA 100mA 300mA Residual current breaker with over-current protection (RCBO) — combines the functions of an RCD and an MCB in one package. In the United States and Canada, panel-mounted devices that combine ground (earth) fault detection and over-current protection are called Ground Fault Interrupter (GFI) breakers; a wall mounted outlet device or separately enclosed plug... |
Zhejiang KRIPAL Electric Co., Ltd.
Zhejiang |
![]() |
Place of Origin:China ... Description: Introducing our GFCI/RCD (Ground Fault Circuit Interrupter/Residual Current Device) product, designed specifically for spa centers and similar places where safety is a top priority. This essential safety plug is rated at 16A 250V IP65, ... |
Shenzhen Heng-Well Electric Co., Ltd.
|
![]() |
Brand Name:HAROK Model Number:VRL22 Place of Origin:CHINA ...Ground Fault Circuit Interrupter 1. General VRL22 residual current operated circuit breakers with overcurrent protection (RCBO) are suitable for lines with AC 50/60Hz, rated voltage 240V/415V, rated current up to 63A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Categories:Dual Function Circuit Breakers Country/Region:china ...Circuit Breakers are specifically designed to provide protection from both arc fault and ground fault hazards. They are certified to meet the CE, RoHS and UL standards for safety and reliability. With a five-year warranty, they are considered to be the highest quality and most reliable circuit... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:HAROK Model Number:VRL03 Place of Origin:CHINA ...Ground Fault Circuit Breaker 1. General VRL03 Ground Fault Circuit Breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, rated current up to 50A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:HAROK Model Number:VKL003 Place of Origin:CHINA ...GROUND FAUL CIRCUIT INTERRUPTER 1. General VKL003 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:HAROK Place of Origin:CHINA ... Current Device adaptor. It is designed to detect and interrupt any fault current that may occur in an electrical circuit. The PRCD adaptor can be connected to any standard electrical socket and then the electrical device is then plugged into the PRCD |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:CHENXIN Model Number:CX-UL03 Place of Origin:CHINA ...Plug Insert 3 Wire Grounding Plug Feature: 1. Material: Copper 2. Easy to use 3. Light weight and convenient to carry 4. Good after-sale service 5. The input power shall decrease and no demage when the output short-circuit,and shall be self-recovery when the fault... |
Chenxin Automation Equipment(Guangzhou) Co., Ltd.
Guangdong |
![]() |
Brand Name:Tianyihongda Model Number:TYHD-AI3 Place of Origin:Beijing,China ...grounded and short circuit fault passage indicator is installed on the overhead power lines, is to detect the grounded and short circuit fault for overhead line. It will alarm during the day and flash during night to show the fault.According to the alarm information , the operator can locate the fault area quickly and find out the point of fault, which supply the best solution for the difficulty in finding fault... |
Beijing Tianyihongda Science & Technology Development Co., LTD
Beijing |
![]() |
Brand Name:Tianyihongda Model Number:TYHD-AI2 Place of Origin:Beijing,China ...grounded and short circuit fault passage indicator is installed on the overhead power lines, is to detect the grounded and short circuit fault for overhead line. It will alarm during the day and flash during night to show the fault. According to the alarm information , the operator can locate the fault area quickly and find out the point of fault, which supply the best solution for the difficulty in finding fault... |
Beijing Tianyihongda Science & Technology Development Co., LTD
Beijing |
![]() |
Brand Name:TYHD Model Number:TYHD-AI1 Place of Origin:China,Beijing ...l alarm during the day and flash during night to show the fault. According to the alarm information , the operator can locate the fault area quickly and find out the point of fault, which supply the best solution for the difficulty in finding fault area. |
Beijing Tianyihongda Science & Technology Development Co., LTD
Beijing |
![]() |
Brand Name:FAIRCHILD Model Number:RV4141AMT Place of Origin:Original RV4141AMT Electronics IC Chips Integrated Circuits IC Component Low Power Ground Fault Interrupter Features • Powered from the AC line • Built-in rectifier • Direct interface to SCR • 500 µA quiescent current • Precision sense amplifier • ... |
Anterwell Technology Ltd.
Guangdong |
![]() |
Brand Name:FAIRCHILD Model Number:RV4141AMT Place of Origin:Original RV4141AMT Electronics IC Chips Integrated Circuits IC Component Low Power Ground Fault Interrupter Features • Powered from the AC line • Built-in rectifier • Direct interface to SCR • 500 µA quiescent current • Precision sense amplifier • ... |
ChongMing Group (HK) Int'l Co., Ltd
|
![]() |
Brand Name:Huaying Model Number:HYCF Place of Origin:Wuhan Hubei China ...Ground Power Digital Cable Fault Tester Cable Fault Finding Equipment Product Introduction Cable Fault Detector is a testing device of good integrity. It can test on the High Resistance Flashover Fault, Grounding High and Low Resistance Fault, Short & Off Circuit on the Cable Fault and Poor contact and etc. If being equipped with sounding method and locating instrument, it can exactly detect the fault... |
Wuhan Huaying Electric Power Tech & Science Co., Ltd
Hubei |
![]() |
Brand Name:Fullde Model Number:FNGR-10.5KV-150A-0.15-10S-41 Place of Origin:Dongguan,China ...arc suppression coil grounded. Suitable for single phase grounding fault during operation of generator,when arc occurs to the fault point, the winding insulation damage scope will be further increased causing short circuit between phase or turns.For this |
Guangdong Fullde Electrical Technology Co., Ltd
Guangdong |
![]() |
Place of Origin:Zhejiang, China Brand Name:XK Model Number:ZN63-8218 ... by a short circuit, which generally results from an overload. Its basic functionality is to interrupt the flow of current after a fault is detected. A vacuum circuit breaker is such kind of circuit breaker where the arc quenching takes place in vacuum. |
ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD
Zhejiang |