Sign In | Join Free | My chinaqualitylighting.com |
|
All ground fault circuit interrupter wiring wholesalers & ground fault circuit interrupter wiring manufacturers come from members. We doesn't provide ground fault circuit interrupter wiring products or service, please contact them directly and verify their companies info carefully.
Total 542 products from ground fault circuit interrupter wiring Manufactures & Suppliers |
|
![]() |
Brand Name:HAROK Model Number:VDL006 Place of Origin:CHINA *, *::before, *::after {box-sizing: border-box; } * {margin: 0; } html, body {height: 100%; } body {line-height: 1.5; -webkit-font-smoothing: antialiased; } img, picture, video, canvas, svg {display: block; max-width: 100%; } input, button, textarea, ... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:Greef Model Number:GT-PCTC Series Controller Place of Origin:Qingdao Product Description: Technologically speaking, the Grid-Tied Controller is the most critical component in on-grid wind generators. Its purpose is to convert Three AC currents from the wind turbine into DC currents before sending them to the inverter. The ... |
Qingdao Greef New Energy Equipment Co., Ltd
Shandong |
![]() |
Brand Name:HAROK Model Number:VRL22 Place of Origin:CHINA ...Ground Fault Circuit Interrupter 1. General VRL22 residual current operated circuit breakers with overcurrent protection (RCBO) are suitable for lines with AC 50/60Hz, rated voltage 240V/415V, rated current up to 63A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:KRIPAL Model Number:UKB7LE Place of Origin:China ...Circuit Breaker 10mA 30mA 100mA 300mA Residual current breaker with over-current protection (RCBO) — combines the functions of an RCD and an MCB in one package. In the United States and Canada, panel-mounted devices that combine ground (earth) fault detection and over-current protection are called Ground Fault Interrupter... |
Zhejiang KRIPAL Electric Co., Ltd.
Zhejiang |
![]() |
Brand Name:KRIPAL Model Number:UKB7LE Place of Origin:China ...Circuit Breaker 10mA 30mA 100mA 300mA Residual current breaker with over-current protection (RCBO) — combines the functions of an RCD and an MCB in one package. In the United States and Canada, panel-mounted devices that combine ground (earth) fault detection and over-current protection are called Ground Fault Interrupter... |
Zhejiang KRIPAL Electric Co., Ltd.
Zhejiang |
![]() |
Brand Name:HAROK Model Number:VRL03 Place of Origin:CHINA ...Ground Fault Circuit Breaker 1. General VRL03 Ground Fault Circuit Breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, rated current up to 50A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Categories:Dual Function Circuit Breakers Country/Region:china ...Circuit Breakers are specifically designed to provide protection from both arc fault and ground fault hazards. They are certified to meet the CE, RoHS and UL standards for safety and reliability. With a five-year warranty, they are considered to be the highest quality and most reliable circuit... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:HAROK Model Number:VKL003 Place of Origin:CHINA ...GROUND FAUL CIRCUIT INTERRUPTER 1. General VKL003 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit... |
Yueqing Vorax Electric CO.,LTD
Zhejiang |
![]() |
Brand Name:Edgarcn Place of Origin:DongGuan in China Model Number:Edgarcn wireharness ... cables are un-coupled, the ground circuit is interrupted and the machine will not operate. The components are held to the cable by flat head screw that is screwed into a thread insert. The threaded insert is attached to one wire inside the cable as the |
Edgar Auto Harnesses LTD.
Guangdong |
![]() |
Brand Name:Tianyihongda Model Number:TYHD-AI3 Place of Origin:Beijing,China ...grounded and short circuit fault passage indicator is installed on the overhead power lines, is to detect the grounded and short circuit fault for overhead line. It will alarm during the day and flash during night to show the fault.According to the alarm information , the operator can locate the fault area quickly and find out the point of fault, which supply the best solution for the difficulty in finding fault... |
Beijing Tianyihongda Science & Technology Development Co., LTD
Beijing |
![]() |
Brand Name:Tianyihongda Model Number:TYHD-AI2 Place of Origin:Beijing,China ...grounded and short circuit fault passage indicator is installed on the overhead power lines, is to detect the grounded and short circuit fault for overhead line. It will alarm during the day and flash during night to show the fault. According to the alarm information , the operator can locate the fault area quickly and find out the point of fault, which supply the best solution for the difficulty in finding fault... |
Beijing Tianyihongda Science & Technology Development Co., LTD
Beijing |
![]() |
Brand Name:TYHD Model Number:TYHD-AI1 Place of Origin:China,Beijing ...l alarm during the day and flash during night to show the fault. According to the alarm information , the operator can locate the fault area quickly and find out the point of fault, which supply the best solution for the difficulty in finding fault area. |
Beijing Tianyihongda Science & Technology Development Co., LTD
Beijing |
![]() |
Brand Name:United electrical Model Number:HZGZ Place of Origin:Wuhan, China ...Grounding Electrical Cable Fault Testing Equipment Product Description: The HZGZ cable fault testing system is a comprehensive cable fault detection instrument. It can test the high resistance flashover fault of the cable, grounding of high low resistance, short circuit and cable wire-broken and poor contact fault... |
Wuhan HeZhong Electric Equipment Manufacture Co.,Ltd
Hubei |
![]() |
Brand Name:FAIRCHILD Model Number:RV4141AMT Place of Origin:Original RV4141AMT Electronics IC Chips Integrated Circuits IC Component Low Power Ground Fault Interrupter Features • Powered from the AC line • Built-in rectifier • Direct interface to SCR • 500 µA quiescent current • Precision sense amplifier • ... |
Anterwell Technology Ltd.
Guangdong |
![]() |
Brand Name:FAIRCHILD Model Number:RV4141AMT Place of Origin:Original RV4141AMT Electronics IC Chips Integrated Circuits IC Component Low Power Ground Fault Interrupter Features • Powered from the AC line • Built-in rectifier • Direct interface to SCR • 500 µA quiescent current • Precision sense amplifier • ... |
ChongMing Group (HK) Int'l Co., Ltd
|
![]() |
Brand Name:Huaying Model Number:HYCF Place of Origin:Wuhan Hubei China ...Ground Power Digital Cable Fault Tester Cable Fault Finding Equipment Product Introduction Cable Fault Detector is a testing device of good integrity. It can test on the High Resistance Flashover Fault, Grounding High and Low Resistance Fault, Short & Off Circuit on the Cable Fault and Poor contact and etc. If being equipped with sounding method and locating instrument, it can exactly detect the fault... |
Wuhan Huaying Electric Power Tech & Science Co., Ltd
Hubei |
![]() |
Brand Name:Fullde Model Number:FNGR-10.5KV-150A-0.15-10S-41 Place of Origin:Dongguan,China ...arc suppression coil grounded. Suitable for single phase grounding fault during operation of generator,when arc occurs to the fault point, the winding insulation damage scope will be further increased causing short circuit between phase or turns.For this |
Guangdong Fullde Electrical Technology Co., Ltd
Guangdong |