Sign In | Join Free | My chinaqualitylighting.com |
|
All oltc transformer testing equipment wholesalers & oltc transformer testing equipment manufacturers come from members. We doesn't provide oltc transformer testing equipment products or service, please contact them directly and verify their companies info carefully.
Total 65757 products from oltc transformer testing equipment Manufactures & Suppliers |
|
![]() |
Brand Name:RISING Model Number:RSZRC-20E Place of Origin:China ...Transformer Testing Equipment Double-channel DC Resistance Tester (Temperature Rise) Product Description Transformer DC resistance test is one of the most important test items in the factory test for finished product and semi-finished product, installation and hand-over test in the transformer manufacturing and in the preventive test... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:RISING Model Number:RSZRC-20S Place of Origin:China ...Transformer Testing Equipment Three-channel DC Resistance Tester Product Description Transformer DC resistance test is one of the most important test items in the factory test for finished product and semi-finished product, installation and hand-over test in the transformer manufacturing and in the preventive test... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:RISING Model Number:RSZRC-40A Place of Origin:China ...Transformer Testing Equipment Single-channel DC Resistance Tester Product Description Transformer DC resistance test is one of the most important test items in the factory test for finished product and semi-finished product, installation and hand-over test in the transformer manufacturing and in the preventive test... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:RISING Model Number:RSZRC-50A Place of Origin:China ...Transformer Testing Equipment Single-channel DC Resistance Tester Product Description Transformer DC resistance test is one of the most important test items in the factory test for finished product and semi-finished product, installation and hand-over test in the transformer manufacturing and in the preventive test... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:RISING Model Number:RSR3310 Place of Origin:China ...Transformer Testing Equipment Three-channel DC Resistance Tester Product Description The transformer DC resistance is a required test item for the factory test, installation and handover test of semi-finished products and finished products in transformer manufacturing, as well as the preventive test... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:RISING Model Number:RS2005S Place of Origin:China ...Transformer Testing Equipment Double Channel DC Resistance Tester Product Description The transformer DC resistance is a required test item for the factory test, installation and handover test of semi-finished products and finished products in transformer manufacturing, as well as the preventive test... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:GDZX Model Number:ZXR-100A Place of Origin:Hubei, China High Accuracy ZXR -100A Transformer Testing Equipment Dc Winding Resistance Test ZXR-100A Transformer Winding Resistance Tester adopts the new power technology, small volume, light weight, large output current, good repeatability, strong anti-interference ... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Brand Name:RISING Model Number:RSSBF Place of Origin:China ...Transformer Testing Equipment Triple Frequency Generator Product Description The product is designed to meet the triple frequency induced withstand voltage test and partial discharge test in GB1094.3 - 85, GB1207 and Preventive Test Code for Electric Power Equipment-1995. The transformer induced withstand voltage test is one of the most important test... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:RISING Model Number:RSBYKC-2000 Place of Origin:China ... that the current on-load tap-changers of power transformers are backward in the measurement methods, without the dedicated measurement means. It can timely diagnose the potential faults of the on-load tap-changer in the power equipment preventive test and |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:huaying Model Number:HYZC-40A Place of Origin:China. mainland ... resistance testing of the transformer winding is a must...In general, to measure the transformer winding or large power output inductor equipment, the traditional electrical bridge method and pressure drop method require much time and energy. Thus, to |
Wuhan Huaying Electric Power Tech & Science Co., Ltd
Hubei |
![]() |
Brand Name:Pego Tester Model Number:HYHL-100A Place of Origin:China ...designed according to IEC62271. The main application of the tester is measurement of circuit breaker contact resistance. All the test results of the tester can be printed by the micro-printer which is integrated in the tester. All the test results saved in |
Pego Electronics (Yi Chun) Company Limited
Jiangxi |
![]() |
Brand Name:Huaying Model Number:HYRZ-903 Place of Origin:Wuhan Hubei China ...Transformer Testing Equipment Frequency Response Characteristic Of Winding 1. Equipment Description: Power transformer as an important electrical equipment, its safe and reliable operation is extremely important for power systems. After the impact of short-circuit current, the transformer winding deformation test... |
Wuhan Huaying Electric Power Tech & Science Co., Ltd
Hubei |
![]() |
Brand Name:RISING Model Number:RS1000 Place of Origin:China ...Transformers Testing Equipment Transformer Load and No Load Tester Capacity Tester Product Description Comprehensive active transformer characteristic-capacity tester is a high precision instrument researched and developed by our company exclusively for measurement of transformer capacity and loss parameters. It is equipped... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:GDZX Model Number:GTB Place of Origin:Hubei, China ...Transformer Testing Equipment , Running Continuously Technical indicators 1 Output voltage waveform: sine wave 2 Output waveform distortion rate: ≤1% 3 No-load loss: 0.2% ~ 0.35% 4 Induction voltage level: 1.1 rated voltage /1min 5 Short-circuit impedance of the single test transformer... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Brand Name:RISING Model Number:RSZR-01 Place of Origin:China ..., installation, overhaul, change of tap switch, handover test and preventive test of power department.It can check the welding quality of the winding joints and whether there is a short-circuit between the winding. It can detect whether the contact of each |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:RISING Model Number:RSBTC-V Place of Origin:China ... of transformer and to conduct harmonic test and analyze to the 31st harmonics. Feature/Function 1. Able to measure the no-load current, no-load loss, short circuit voltage, short circuit (loading) loss of transformer. 2. Able to conduct harmonic test and |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:RISING Model Number:RS6810A Place of Origin:China ...Transformer Testing Equipment TTR -5C~40C Temperature 12kg Weight Product Description In the production process of semi-finished products and finished products of power transformers, before the newly installed transformers are put into operation and according to the preventive test regulations of the Ministry of electric power of the people's Republic of China, it is required to test... |
Wuhan Rising Electric Co., Ltd.
Hubei |