Sign In | Join Free | My chinaqualitylighting.com |
|
All victor 05 loop calibrator wholesalers & victor 05 loop calibrator manufacturers come from members. We doesn't provide victor 05 loop calibrator products or service, please contact them directly and verify their companies info carefully.
Total 947 products from victor 05 loop calibrator Manufactures & Suppliers |
|
![]() |
Brand Name:FY Model Number:4.01-6.86-9.18 Place of Origin:Henan Calibration Test Powder Packets For PH Probe Calibration Buffer Solution : PH Probe Calibration Buffer Solution Calibration Method : 1. Firstly, 6.86 calibration powder is poured into 250ml distilled water or pure water and stirred well. Then, the power... |
FY EP Sci-Tech Co., Ltd
Henan |
![]() |
Brand Name:GFUVE Model Number:GF312B Place of Origin:BEIJING,CHINA Accuracy 0.05%, 0.1%, 0.2% Power supply 220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz Test Voltage Range 0V-600V Error ±0.05% (30V-600V) ±0.1% (5V-30V) Harmonic 2nd-63st Test Current Range (direct connection) 20mA-20A Error (direct connection) ±0.05% (100mA-... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Place of Origin:ZHEJIANG,CHINA Brand Name:SHENGDI TECHNOLOGY Model Number:HS6103F ... CHANGE TO CALIBRATE/TEST LINE AND NEUTRAL This specification for single phase dual loop energy meter test bench. Voltage Source: 1. Output Voltage Range: 0- 275/300V 2. Output Max Power: 800VA 3. Resolution: 0.01% 4. Stability: Better than 0.05% / 3 Min... |
Zhejiang Shengdi Technology Inc.
|
![]() |
Brand Name:Yunyi Model Number:JY-60 Place of Origin:China Calibration Yunyi 0.05 Accuracy Deadweight Tester Calibration 36000psi Description Yunyi 0.05 Accuracy Deadweight Tester Calibration 36000psi JY series piston gauge is our new R & D product manufactured according to the latest national "piston gauge" test ... |
Xi'an Yunyi Instrument Co., Ltd
|
![]() |
Brand Name:GENY Model Number:YC-1891GT Place of Origin:China ...05/0.1 Rail-mounted Energy Meter Calibration Device The YC1893GT series rail-mounted energy meter calibration device meets the technical specifications and testing methods outlined in the national standards GB/T11150-2001 and the regulations JJG597-2005. Device Features Convenient calibration characteristics Professional calibration... |
Guangzhou GENY Electric Co., Ltd
|
![]() |
Brand Name:GFUVE Model Number:GF302D1 Place of Origin:China GF302D1 Portable three phase kwh meter tester (Accuracy 0.05% or 0.1%) Application The GF302D1 Portable three phase kwh meter tester consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase ... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:KRE Model Number:KE8301F Place of Origin:China ... an isolation voltage transformer. Description KE8301 is high-performance calibration equipment for three-phase electricity meters, which combines characteristics of different users in different fields including power supply, metrology and manufacturer of |
Guangzhou Kingrise Enterprises Co., Ltd.
Guangdong |
![]() |
Brand Name:PANRAN Model Number:PR9141C Place of Origin:Tai'an,China Accuracy 0.05%F.S High Precision Handheld Pumps For Pressure Calibration PR9141 series of hand-held pneumatic pump can be used for laboratory or on-site environment, with simple operation, step-down and steady, fine ... |
Changsha Panran Technology Co., Ltd.
Hunan |
![]() |
Brand Name:GFUVE Model Number:GF312V2 Place of Origin:BEIJING,CHINA ...calibrator is with comfort design, small size, and light weight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use. TECHNICAL PARAMETERS Accuracy class 0.05%, 0.1% Power Supply External power, 220V/110V, 50/60Hz Voltage measurement Range 30-560V Error ±0.05... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GFUVE Model Number:GF312V2 Place of Origin:BEIJING,CHINA ...05% Screen capture function Input two pulse signal for master and slave meter synchronously calibration Large size display screen, direct viewing and convenient Internal communication port for PC control Multiple power supply for different testing occasion Large capacity storage device for mass memory TECHNICAL PARAMETERS Electrical parameters Accuracy class 0.05... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GFUVE Model Number:GF102 Place of Origin:BEIJING,CHINA ... 500 sets energy meter data Overload, short circuit, open circuit protection Electrical parameters Accuracy class 0.05%, 0.1% Power supply One Phase AC 85-265V, |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GFUVE Model Number:GF312V2 Place of Origin:BEIJING,CHINA ...05% Screen capture function Input two pulse signal for master and slave meter synchronously calibration Large size display screen, direct viewing and convenient Internal communication port for PC control Multiple power supply for different testing occasion Large capacity storage device for mass memory PARAMETERS Electrical parameters Accuracy class 0.05... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:JUTAI Model Number:LD-100 LD-200 Place of Origin:Shenzhen China ...Loop Sensor | Single Channel, Precise Detection & Built-in Diagnostics The Inductive Loop Sensor redefines reliability in vehicle detection with its unparalleled precision and self-monitoring capabilities, engineered for demanding environments like toll lanes, industrial gates, and urban intersections. Featuring 16-level sensitivity calibration... |
Shenzhen Jutai Comm Co., Ltd.
|
![]() |
Brand Name:GDZX Model Number:ZX3030B Place of Origin:CHINA ZX3030B AC/DC Three Phase Standard Power Source Introduction ZX3030B AC/DC Three Phase Standard Power Source adopts advance ARM+FPGA, high precision D/A conversion and DDS technologies, can set up and regulate parameters of voltage, current, frequency, ... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Brand Name:GDZX Model Number:ZX1030 Place of Origin:China ... source, and amplify signal power. It’s with high precision standards of voltage, current, power, electric energy inside, by analog closed loop feedback and digital PID control it can output voltage, current, |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Brand Name:GDZX Model Number:ZXHQ-Y Place of Origin:Hubei, China ...Calibrator Transformer CT PT Analyzer Product introduction the Transformer CT PT Analyzer can obtain the excitation characteristics of the current and voltage transformers, excitation parameters. The maximum inflection point voltage of the current transformer under test can reach 45kV with various test parameters such as ratio, hit ratio error, polarity, coil resistance and hysteresis loop... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Brand Name:PANRAN Model Number:PR9111 Place of Origin:Tai’an,China High Precision Digital Pressure Gauge With Calibration Certificate Main Application: 1.Calibrate general Pressure gauge 2.Verify the precision pressure gauge 3.Calibrate the blood pressure gauge 4.Calibrate other pressure gauges 5.Precision pressure ... |
Changsha Panran Technology Co., Ltd.
Hunan |
![]() |
Model Number:TD1600 Place of Origin:China Brand Name:TUNKIA ...AC Calibrator Introduction TD1600, a single-phase AC calibrator with wide range, high precision and multifunction. The apparatus can output high accuracy AC voltage, current and power, and the optional accuracy are 0.05% and 0.02%. Applied to calibrate ... |
Tunkia Co., Ltd.
|
![]() |
Model Number:TD1600 Place of Origin:China Brand Name:TUNKIA ...AC Calibrator Introduction TD1600, a single-phase AC calibrator with wide range, high precision and multifunction. The apparatus can output high accuracy AC voltage, current and power, and the optional accuracy are 0.05% and 0.02%. Applied to calibrate ... |
Tunkia Co., Ltd.
|
![]() |
Place of Origin:China Brand Name:TUNKIA ...Calibration Device for Clamp Meter Introduction TD1050A, a calibration device for clamp ammeters. The optional accuracy are 0.02% and 0.05%. The device calibrates the AC/DC clamp ammeters by single coil with high accuracy and easy traceability, and has the functions of AC/DC current output, resistance simulation, frequency/phase adjustment, power detection. Meet the requirements of JJF 1075-2015 Calibration... |
Tunkia Co., Ltd.
|